Measure the density of small solid specimens with the Ray-Ran Auto Density Measurement System. Choose three or six temperature-controlled gradient columns, with automatic density calculation and Techni-Test software for analysing results.
The Advanced Auto Density Gradient Apparatus from Ray-Ran has become the world’s benchmark for accurate density measurement of small solid specimens using the column method.
Built with operator simplicity in mind, its ease of operation and high accuracy makes it ideal for density testing during product development and quality control within production, research and development labs and teaching institutions.
Our Auto Density Measurement apparatus is supplied with built in digital temperature control to ensure the temperature of each column is at 23°C+/- 0.1°C. For ambient temperatures in excess of 23°C the integrated cooling coil can be used in conjunction with an optional water chiller unit so the correct temperature can be maintained. This can be even more accurately controlled using the optional microprocessor-controlled water flow valve kit.
Available in three- or six-column configurations, the system calculates specimen density from its position relative to calibrated marker floats. The operator records the sample position using the microscope and position-measurement system, and the density is displayed on the LCD. Column linearity can also be reviewed in Techni-Test software.
Density gradient columns are a way of determining the density measurement of polymers, resins, plastics and more.
To build a column, a peristaltic pumped filling system is supplied with the Advanced Auto Density Gradient Apparatus from Ray-Ran Column filling speeds are variable from 0.5l/hr to 1.5l/hr.
The resulting solution has a density which, when introduced into the column, increases uniformly from top to bottom. Calibrated glass marker floats with known densities are introduced into the column and sink to a point where their density matches the solution.
A linear encoder which is attached to a trammel guide is used to calibrate the gradient of the column by focusing the optical microscope onto the center of the calibrated float and entering the floats density value into the microprocessor. Once test samples have been introduced into the column and have reached a point of static equilibrium, they are accurately sighted using the microscope.
The resultant density of the sample is obtained and displayed on the LCD without the need for complicated graphs. An automatic sweep mechanism is used to extract the floats and samples from each column.
The on-board LCD provides simple on-screen instruction and using the alpha/numeric keypad test parameters, such as operator list, material reference numbers and batch numbers, can be entered and stored for results presentation. Batch statistics of mean, standard deviation and co-efficient of variation are automatically updated after each test and results are shown in graphical and tabular format for analysis when downloaded to the supplied Techni-Test PC software.
Tell us which materials you test, their expected density range, your test method and typical sample workload. Include your laboratory temperature and any space constraints. You can enquire before deciding whether you need three or six columns.
Our team can discuss the configuration and supporting equipment with you. Before ordering, ask us to confirm which marker floats, filling equipment, cooling options and software are included in the quotation, together with delivery and setup arrangements.
The published product information lists a traceable calibration certificate and a one-year return-to-base warranty. Ask us to confirm the terms for your order and discuss calibration, maintenance or operator familiarisation options for your equipment and location.
SKU: RR/DGA
Applications: Density Testing
Materials: Elastomers, Film
Weight (3 column): 70 kg
Weight (6 column): 80 kg
Dimensions (3 column): 850 x 400 x 1110 mm (W x D x H)
Dimensions (6 column): 1200 x 400 x 1110 mm (W x D x H)
Power: 110-240 VAC, 50-60 Hz
Display: 160 x 128 dots graphic LCD module with alphanumeric keypad
The gradient column method uses a liquid column with a density that increases uniformly from top to bottom. When a specimen is placed in the column, it sinks to the point where its density matches the surrounding liquid. Calibrated glass marker floats are used as reference points, and the system uses an optical microscope to determine the specimen’s position, from which density is automatically calculated and displayed on the LCD.
The system includes built-in digital temperature control maintaining each column at 23°C +/- 0.1°C. For laboratories where ambient temperature exceeds 23°C, an integrated cooling coil can be used with an optional water chiller. An optional microprocessor-controlled water flow valve kit is available for tighter control.
The 3-column version (850 x 400 x 1110 mm, 70 kg) suits laboratories with lower throughput requirements or limited space. The 6-column version (1200 x 400 x 1110 mm, 80 kg) supports higher sample volumes or multiple density ranges tested simultaneously. Both configurations include the same core measurement, software and temperature control features.
The system is supplied with Techni-Test PC software, automatic density calculation, a variable-speed pumped filling system, twin conical filling flasks, automatic magnetic stirrer, automatic sweep mechanism, a 7x optical microscope, a traceable calibration certificate and a 1-year return-to-base warranty. Optional accessories include glass marker floats (0.7-2.2 g/ml), a microprocessor-controlled filling system and water chiller options.
The system is designed for density measurement of small solid specimens including polymers, resins, plastics and elastomers, in line with ASTM D1505 and ISO 1183. Contact our team to discuss suitability for materials outside these applications.
Lab needed the right instrument for every test → Partnered with Industrial Physics → Testing needs covered across the lab ✓
Some paint manufacturers have to undertake so many different types of tests that it’s hard to stay on top of the demands of their industry and the changing technologies that can best support them.
This was the case for our valued customer. They needed the equipment, skills, experience, and collaboration of a genuine partner. One offering personalized support and guidance identifying the correct inspection solution for each situation. We are always delighted to help.
Daniel Marschall, President of Marschall Labs, said:
“The professionals at Industrial Physics took the time to understand the specific testing equipment needs of our lab. I can’t say enough about the excellent customer service and support they provide.”
© 2026 Industrial Physics. All rights reserved. Privacy Policy Manage consent