TQC Sheen CurveX 3 Nano Oven recorder for can coaters

The  CurveX 3 Nano is a 4-channel oven data logger specially designed for can coaters. It’s a reliable oven temperature recorder that makes data logging easy, so you can ensure that the time-temperature cycle during can coating is at the required level.

Description

The CurveX 3 Nano Oven temperature recorder for can coaters

Keep an eye on the time-temperature cycle during can coating, with this efficient oven data logger that’s very easy to operate. Our reliable oven data logger winds through the oven’s conveying system alongside the cans being coated, ensuring a complete temperature profile. It’s a simple yet reliable oven temperature monitoring system perfect for can coaters.  

With the help of paint cure specifications, our compact oven data logger determines the curing process by calculating the cure index for you, enabling a simple pass/fail setup. From a computer, you can analyze all gathered data with TQC Ideal Finish Analysis software and print a report with all measurement data and graphs for a comprehensive oven temperature monitoring system. 

Improve the efficiency of your process and save energy by using the CurveX Oven Data Logger to determine the exact heat and amount of time your can coatings need to cure.   

Why choose the CurveX 3 Nano Oven temperature recorder?

This reliable oven data logger offers several important benefits, making it easy to monitor your oven temperature during can coating. These include:   

An oven data logger that’s built to last

The CurveX 3 Nano is built into a stainless-steel casing and has a canshaped form factor. The housing is extremely durable and impact resistant, ensuring it’s an oven temperature recorder you can rely on. It also features industrialtype USB connectors and rechargeable batteries. It comes factory calibrated and has a large memory and 10 different batches to store data.   

4-channel input

The TQC Sheen CurveX 3 Oven Data Logger has four thermocouple type K inputs to be used to measure either surface or air temperature. It comes complete with 4 wire probes and self-adhesive attachment pads to position the probes, which are usually attached to a real can on the next pin.  

Both inside or outside end-caps

Designed to test the coating both inside and outside a can, this oven data logger comes complete with end caps designed for each application.  

Easy to use oven temperature monitoring system

Set the paint type and other parameters of the CurveX 3 Nano with the Ideal Finish Analysis software on your PC and download the results. Get the results you need, when you need them. Use this durable oven data logger and get easy-to-read results.

Specifications

SKU: CX3040

Applications: Temperature and Climatic Testing

Materials: Aluminum, Metal, Steel

Measuring range: 0°C to 300°C / 32°F to 572°F

Operating temperature: 0°C to 60°C / 32°F to 140°F

Maximum time in oven:  10 minutes at 300 °C / 10 minutes at 572 °F – 12 minutes at 250 °C / 10 minutes at 482 °F – 15 minutes at 200 °C / 10 minutes at 392 °F – 19 minutes at 150 °C / 10 minutes at 302 °F – 30 minutes at 100 °C / 10 minutes at 212 °F

Accuracy: ±1°C / 1.8°F

Channels: 4

Sample interval time: 1s to 60 min

Memory: 10 batches with 16000, or 1 batch with 160000 readings

Display: Three multi-colour LED’s

Interface: USB

Housing material: 51 x 210 mm / 2.00 x 8.27 inch

Power supply: Rechargeable battery

:

Inside and outside end-caps: Included

Battery life time: 120 hour continuous use

Weight: 850 g / 30 oz

Features & Benefits

  • Easy to operate through only 3 buttons 
  • Meaningful feedback of multi colored LED’s 
  • Factory calibrated for immediate use 
  • Downloads data through a standard USB port 
  • Rechargeable battery pack through USB connector 
  • Large memory of max. 160.000 readings 
  • Memory for 10 different batches, automatically overwrites the oldest results 
  • Programmable “paint type” memory for immediate “pass / fail” result 
  • Round design, only 53 mm in diameter, for use in can ovens 
  • Compatible with Ideal Finish Analysis software 
  • Complete paint library and Ideal Finish Analysis software support 

Interested in this product?

Please select product variables here Make an Inquiry Request a Quote Request a Quote

Do you own this product?

Please select product variables here Get Product Support Get Product Support Arrange a Service Arrange a Service

Customer Success Story

High energy costs → Adopted advanced temperature data logger → Accurate insights into oven curing times unlocked ✓

The Problem

Industrial processes are often energy heavy, expensive and harmful to the planet. Sadly, many companies don’t appreciate how easily they can optimize their operational efficiency.    

The Solution

If you use industrial powder coating ovens then Industrial Physics can empower you to better understand your energy use with tools like the TQC Sheen CurveX temperature data-logger 

The Result

Learn how our aluminium profiling customer managed to cut their energy use by a third, slashing costs and helping them to offer a more sustainable service in the process. 

Can't find what you are looking for?