Back to Product Search

Slideshow Items

TQC Sheen Probes for PosiTector 6000 – Ferro & Non-Ferro

A wide range of high-performance probes designed for use with the PosiTector 6000 coating thickness gauge. Suitable for both ferrous and non-ferrous substrates, including specialized probes for duplex coatings and extreme conditions.

Price range: £413.00 through £1,396.00 Ex. VAT

Dispatched within 2 weeks

Pay securely with

Want to make sure this is the right fit before you get in touch?

Description

The TQC Sheen Probes for the PosiTector 6000 series offer a versatile and robust solution for measuring coating thickness across a wide variety of metal substrates. Whether you need to measure a few microns of paint or several millimeters of protective coating, there is a probe in this range to suit your application. With options for ferrous, non-ferrous, and combined (FN) materials, these probes work in combination with the PosiTector 6000 to help ensure consistent coating quality and compliance with industry standards.

Why Coating Thickness Testing Matters

Accurate coating thickness measurement is critical in industries where performance, longevity, and regulatory compliance are essential. An under-applied coating can lead to premature corrosion or product failure, while an overly thick layer may result in unnecessary material costs or mechanical issues. By using the appropriate probe for your substrate and coating type, you can verify application quality, optimize production processes, and extend the service life of your products.

How to Choose the Right Probe for Your Application:

Identify your substrate material

  • Choose F for ferrous (steel, iron)
  • Choose N for non-ferrous (aluminum, copper, etc.)
  • Choose FN for dual (ferrous/non-ferrous or unknown)
  • Choose FNDS for duplex coatings (e.g., paint over galvanization)

Determine the coating thickness range

  • Standard: Up to 60 mils (1500 μm)
  • High-range: Up to 500 mils (13 mm) or more
  • Select a probe that matches or exceeds your maximum expected thickness

Consider the measurement environment

  • Integral probes are compact and ideal for tight or mobile use
  • Cabled probes provide flexibility for hard-to-reach areas
  • Xtreme™ probes are built for harsh or high-temperature conditions

Account for part geometry and accessibility

  • Use angled probes (0°, 45°, 90°) for curved or confined surfaces
  • Microprobes are ideal for small or precision-critical areas
  • Extended-length cables are available for large structures or remote access
SKU  Probe model  Substrate  Probe Style  Measuring range 
LD6025 F Ferrous Integral 0 – 60 mils (0 – 1500 μm)
LD6099 FS Ferrous Regular cabled 0 – 60 mils (0 – 1500 μm)
LD6021 FXS Xtreme™ Ferrous Regular cabled 0 – 80 mils (0 – 2000 μm)
LD6017 FRS Ferrous 90° regular cabled 0 – 60 mils (0 – 1500 μm)
LD6100 F0S Ferrous 0° microprobe 0 – 45 mils (0 – 1150 μm)
LD6101 F45S Ferrous 45° microprobe 0 – 45 mils (0 – 1150 μm)
LD6102 F90S Ferrous 90° microprobe 0 – 45 mils (0 – 1150 μm)
LD6026 FT Ferrous Integral 0 – 250 mils (0 – 6 mm)
LD6018 FTS Ferrous high-range cabled 0 – 250 mils (0 – 6 mm)
LD6014 FHXS Xtreme™ Ferrous High-range cabled 0 – 400 mils (0 – 10000 μm)
LD6020 FKS Ferrous High-range cabled 0 – 500 mils (0 – 13 mm)
LD6027 N Non-ferrous Integral 0 – 60 mils (0 – 1500 μm)
LD6104 NS Non-ferrous Regular cabled 0 – 60 mils (0 – 1500 μm)
LD6019 NRS Non-ferrous 90° regular cabled 0 – 60 mils (0 – 1500 μm)
LD6105 NAS Non-ferrous Regular cabled 0 – 25 mils (0 – 625 μm)
LD6106 N0S Non-ferrous 0° microprobe 0 – 25 mils (0 – 625 μm)
LD6107 N45S Non-ferrous 45° microprobe 0 – 25 mils (0 – 625 μm)
LD6108 N90S Non-ferrous 90° microprobe 0 – 25 mils (0 – 625 μm)
LD6024 NKS Non-ferrous High-range cabled 0 – 500 mils (0 – 13 mm)
LD6028 FN Ferrous / non-ferrous Integral 0 – 60 mils (0 – 1500 μm)
LD6109 FNS Ferrous / non-ferrous Regular cabled 0 – 60 mils (0 – 1500 μm)
LD6022 FNRS Ferrous / non-ferrous 90° regular cabled 0 – 60 mils (0 – 1500 μm)
LD6013 FNDS Ferrous / non-ferrous Regular cabled (duplex coating) 0 – 60 mils (0 – 1500 μm)
LD6023 FNTS Ferrous / non-ferrous High-range cabled 0 – 250 mils (0 – 6 mm)
LD6034 FNGS Ferrous / non-ferrous High-range cabled 0 – 2.5 inches (0 – 63.5 mm)

How to Use

These probes are designed for seamless integration with the PosiTector 6000 coating thickness gauge. Simply connect the appropriate probe—either built-in or separate—to your PosiTector gauge or SmartLink device. Place the ruby-tipped probe on the coated surface to take an instant, non-destructive measurement. The probe automatically compensates for substrate type and curvature, ensuring precise results even on irregular or complex surfaces.

Selecting the right probe depends on your specific use case. Begin by identifying the substrate material (ferrous, non-ferrous, or both) and the expected coating thickness range. Consider the shape and accessibility of the test surface—tight areas or unusual geometries may require an angled or mini probe. For high-temperature environments or thick coatings, specialized probes such as the FHXS or FKS series are available.

Smart Connectivity and Flexibility

Each probe is compatible with the PosiTector SmartLink, a wireless device that connects to your smartphone or tablet via Bluetooth. With the free PosiTector app, users can record, store, and share measurement data instantly—turning the probe and your mobile device into a fully functional digital gauge. This flexibility is especially useful for fieldwork, inspections in tight spaces, and applications that require remote data logging or documentation.

Designed for Every Scenario

TQC Sheen’s wide range of probe options includes straight, rectangular, and 90° angled heads, as well as standard and extended measurement ranges—from as little as 0 to 1500 µm, up to 63.5 mm. There are even probes designed specifically for duplex coatings, which can measure the thickness of individual paint and galvanization layers in a single reading. This level of versatility ensures that professionals across industries can find the right solution for their unique needs.

Built for Durability

Each probe is constructed with durability in mind, featuring a strong ruby-tipped sensor that resists wear even after thousands of readings. Cable-mounted probes are built with high-quality materials and are available with extended cable lengths—up to 75 meters—making them ideal for large-scale or hard-to-access surfaces such as storage tanks, pipelines, or structural components.

Specifications

SKU:

Applications: Coating Testing, Thickness Testing

Materials: Metal

F, N, FN, and FNDS Probes: Range from 0–1500 μm to 63.5 mm

FNDS Duplex Coating Probe: Measures individual paint and zinc layers in one reading

High-Temp Probes: Up to 10,000 μm and 250°C (FHXS and FXS series)

Probe Types: Straight, 90° angle, mini, built-in, and removable

Cable Length: Standard 82 cm, extendable up to 75 m

Accuracy (Standard Probes):

±(1 μm + 1%) for 0–50 μm: ±(1 μm + 1%) for 0–50 μm

±(2 μm + 1%) for >50 μm: ±(2 μm + 1%) for >50 μm

Accuracy (Thick Coating Probes):

±(0.01 mm + 1%) for 0–2.5 mm: ±(0.01 mm + 1%) for 0–2.5 mm

±(0.01 mm + 3%) for >2.5 mm: ±(0.01 mm + 3%) for >2.5 mm

Accuracy (Ultra-Thick Coatings):

±(0.2 mm + 3%) for 0–63.5 mm: ±(0.2 mm + 3%) for 0–63.5 mm

Features & Benefits

  • Durable, ruby-tipped sensors for long-term precision
  • Interchangeable probes for maximum flexibility
  • Wide range of sizes and styles for varied applications
  • Wireless compatibility via PosiTector SmartLink
  • Specialized duplex coating probe available
  • Built-in and cabled versions accommodate different measurement angles and geometries
  • Extendable cable length up to 75 meters for large or hard-to-reach surfaces
  • Ideal for standard coatings and extreme conditions alike
  • Strong, wear-resistant ruby-tipped sensors for long-term durability
  • Compatible with ferrous, non-ferrous, and duplex substrates
  • Wide measurement ranges available: up to 63.5 mm (2.5 inches)
  • Straight, angled, mini, and built-in probe designs for different geometries
  • Probes automatically recognize and retain calibration settings
  • Seamless probe interchangeability without recalibration
  • Extended cable lengths available – ideal for remote or underwater testing
  • Heavy-duty, gold-plated locking connector ensures reliable use in industrial environments
  • Certificate of Calibration (Long Form) traceable to NIST or PTB included with each probe
  • One year probe warranty for added peace of mind

Interested in this product?

Please select product variables here Make an Inquiry

Do you own this product?

Please select product variables here Get Product Support Get Product Support Arrange a Service Arrange a Service

Can't find what you are looking for?

Delivery, Returns & Refunds

Products offered on our website are available for delivery to addresses worldwide by UPS Courier Service. If UPS does not deliver to a specific region or country, we will notify you and refund you the total amount of your order, using the original method of payment. You can return products in the original packaging and with proof of purchase subject to terms and conditions. Read more