ISO 75-1 is an international ISO testing standard that defines how to determine the temperature of deflection under load of plastic samples. 

The International Organization of Standards (ISO) produces a wide range of ISO standards to guide manufacturers, production lines and laboratories when checking the integrity of packaging, products, and materials across many industries.  

This plastic testing method is commonly known as the heat deflection temperature test, or heat distortion temperature (HDT) test. Although there’s no official document using this designation. 

What’s covered by the ISO 75 plastic tests? 

There are three parts to the ISO 75 heat deflection temperature test:  

  • ISO 75-1 offers a general approach to determine the temperature of deflection under load (flexural stress under three-point loading) of plastics. Different types of test specimen and different constant loads are defined to suit different types of material. 
  • ISO 75-2 gives specific requirements for filled plastics and fiber-reinforced plastics in which the fiber length, prior to processing, is up to 7.5mm. It also covers ebonite 
  • ISO 75-3 gives specific requirements for high-strength thermosetting laminates and long-fiber-reinforced plastics in which the fiber length, prior to processing, is greater than 7.5mm. 

Analyzing data from the ISO 75 plastic tests  

The methods specified across the three ISO 75 plastic tests are suitable for assessing the relative behavior of plastics and ebonite at elevated temperature under load at a specified rate of temperature increase.  

The results you get don’t necessarily represent maximum applicable temperatures. This is because essential factors such as time, loading conditions and nominal surface stress can differ from the test conditions. True comparability of data can only be achieved for materials with the same room-temperature flexural modulus. 

Data obtained using the ISO 75 plastic testing methods aren’t intended to be used to predict actual end-use performance. It’s also not intended for design analysis or prediction of the endurance of materials at elevated temperatures. 

Our ISO 75 compliant plastic testing devices  

So, how can Industrial Physics improve your ISO 75 heat deflection temperature testing? 

Ray-Ran 3 & 6 Station Heat Distortion & Vicat Softening Point Apparatus 

Developed by Ray-Ran, our plastics testing specialist brand, our HDT/Vicat Apparatus is designed and built to cover multiple international testing standards.

It utilizes microprocessor technology to accurately determine the deflection and softening point characteristics of all thermo-plastic test specimens.  The 3 & 6 station device will test three or six samples simultaneously. 

 

Be sure to check out some of the other plastic testing instruments from across the Industrial Physics portfolio.  

 Industrial Physics is fantastic with plastics!  

We’ve learnt a thing or two about plastic testing over the decades. Now Industrial Physics is recognized as a brand that likes to bring new, innovative plastic and polymer testing devices to market. 

We like to share our experience and lessons learnt across the knowledgebase section of our website. For example, there’s this blog on the signs of creep failure in plastics and polymers. You could also try this one that explains why to test the density of plastic and polymers? 

If you have any questions about ISO 75-1 heat distortion temperature (HDT) testing and how we can help you with other aspects of your plastic testing, then just get in touch!  