A single-station seal-strength and hot tack tester that seals packaging film samples and measures how well they seal, giving you the data to confirm the right sealing conditions before they reach production.
In order to request a quote, arrange a service or make an inquiry about this product you must select modifiers above.
The TMI Büchel SL-25 Hot Tack and Seal Tester is a single-station testing center built for single- or multi-layer flexible film structures. Its main function is to seal film samples and provide data on seal strength, giving you the information you need to confirm the right sealing conditions for your packaging films before they reach production.
On its own, the SL-25 works as a heat sealer, sealing film samples from 1″ to 8″ wide at temperatures, pressures, and dwell times you set. Attach the SL-25 Hot Tack/Seal Test Unit (75-56-01) and testing expands to include Hot Tack, Seal Test, Hot Tack Profile, and Seal Test Profile testing.
The SL-25 connects to a PC of your choice by USB and runs GraphMaster Pro, downloaded and updated through the GraphMaster Download Center. GraphMaster Pro supports test profiles based on temperature, dwell time, and pressure, so you can build test conditions that reflect what actually happens on your line.
The SL-25 has no onboard display or touch screen – everything is controlled from the customer’s PC using GraphMaster Pro.
Test parameters are fully computer-controlled: a temperature set point range of 21-400°C, a seal pressure range of 30-800N (actual pressure depends on jaw area), a dwell time of 0.1-100 seconds, and a peel rate of 1-100mm/sec. A configurable cooling time of 0-6000 seconds gives the seal time to cool before peeling, and you can run groups of up to 100 samples per test series.
Upper and lower sealing temperatures are set independently, so you can run each jaw at its own set point and reproduce the sealing conditions you need. Dual load cells measure the force actually applied to the film, which keeps sealing surface pressure consistent from one sample to the next. Safety guards and switches are fitted as standard.
A set of seal jaws is required to run the SL-25 and is ordered separately. The SL-25 uses the same jaws as the SL-10, so jaws already in your lab for an SL-10 will fit the SL-25, and jaws bought for an SL-25 will work on an SL-10.
Quick change seal jaw inserts let you switch sealing patterns quickly between runs. The phenolic seal jaw tray (75-56-07) gives you somewhere safe to store hot jaw inserts as they cool. A footswitch (49-56-02, the same footswitch used with the TMI Büchel micrometer) lets you cycle the machine hands-free. All of these are ordered separately from the instrument.
The SL-25 requires 120/230 VAC power (standard US units are configured for 120 VAC), a clean, dry air supply at 90-120 PSI, and a surface capable of supporting at least 275 lbs (125kg). An ambient temperature of 18-22°C is recommended for optimal performance.
The main unit measures 22.2 x 22.9 x 22.8 in (563 x 583 x 580 mm), width by height by depth. The Hot Tack/Seal Test Unit adds a further 7.3 x 5.9 x 7.0 in (185 x 150 x 177 mm), so allow bench space for both if you’re running hot tack testing.
The SL-25 conforms to ASTM F1921 for hot tack testing and ASTM F2029 for making heat seals, with calibration to ASTM E-4.
TMI Büchel is part of the Industrial Physics group. The SL-25 is manufactured by Industrial Physics and backed by its global service and support network.
SKU:
Applications: Adhesion Testing
Software: GraphMaster Pro (runs on customer-supplied PC, connected via USB)
Test profile variables: Temperature, dwell time, pressure
Electrical (75-56-0001): 120 VAC
Electrical (75-56-0002): 230 VAC
Power cord: 6 ft (1.8m), 10A; UPS with AVR rated ≥ 1500VA recommended, 15A supply circuit
Sealing width: 1″ to 8″
Seal temperature set point range: 21 to 400°C
Sealing temperature control: Independent upper and lower jaw set points
Seal pressure range: 30 to 800N (actual pressure depends on jaw area)
Load cell configuration: Dual load cells, for consistent sealing surface pressure
Dwell time range: 0.1 to 100 seconds
Cooling time range: 0 to 6000 seconds
Peel rate range: 1 to 100 mm/sec
Jaw length range: 25.4 to 230.2 mm
Jaw width range: 4.9 to 25.4 mm
Samples per test group: 1 to 100
Safety: Safety guards and switches fitted as standard
Air supply: 90-120 PSI, clean and dry (air dryer and filter built in)
Site surface load rating: 275 lbs (125kg) minimum
Recommended ambient temperature: 18-22°C
Temperature resolution: ±0.1°C (32.18°F)
Temperature measuring accuracy: ±0.15°C (32.27°F)
Seal load cell capacity: 1000 lbs (4,448N)
Seal load cell accuracy: 0.89N (0.09kg)
Hot tack load cell capacity: 25 lbs (111.2N)
Hot tack load cell accuracy: 0.1% full scale
Sealing pressure resolution: 0.68kPa (0.1psi)
Sealing dwell time resolution: 10ms
Control accuracy: ±0.025ms
Calibration: ASTM E-4
On its own, the SL-25 functions as a heat sealer, sealing film samples from 1″ to 8″ wide at temperatures, pressures, and dwell times you set.
Attaching the SL-25 Hot Tack/Seal Test Unit (75-56-01) expands testing to include Hot Tack, Seal Test, Hot Tack Profile, and Seal Test Profile testing.
The SL-25 connects to a customer-supplied PC via USB and runs GraphMaster Pro software.
The SL-25 conforms to ASTM F1921 for hot tack testing and ASTM F2029 for making heat seals, with calibration to ASTM E-4.
No. A set of seal jaws is required to run the instrument and is ordered separately. The SL-25 uses the same jaws as the SL-10, so jaws you already own for an SL-10 will fit, and jaws bought for an SL-25 will work on an SL-10. They’re available in standard sizes or custom geometries.
The SL-25 Hot Tack/Seal Test Unit (75-56-01), seal jaws and quick change jaw inserts, the phenolic seal jaw tray (75-56-07), and the footswitch (49-56-02) are all ordered separately as standalone items.
The main unit measures 22.2 x 22.9 x 22.8 in (563 x 583 x 580 mm). If you’re adding the Hot Tack/Seal Test Unit, allow a further 7.3 x 5.9 x 7.0 in (185 x 150 x 177 mm). The bench also needs to support at least 275 lbs (125kg).
© 2026 Industrial Physics. All rights reserved. Privacy Policy Manage consent