MM300 Moisture Transducer For Reliable Moisture Measurement

Moisture Transducer MM300 For Moisture Measurement For integrated, cost effective moisture analysis for OEM's and multiple sampling points

SKU:13941

MM300

Industries:

Materials:

Description

Specifications

Documents

Where simple, accurate moisture measurement is required, the MM300 is the ideal choice.

Designed with the OEM user in mind, the MM300 transducer and monitor can be easily integrated into a wide range of systems. This two wire loop powered dew point transmitter is designed for moisture measurement in gases. Suitable for applications in the petrochemical, power generation and process industries. The 4-20mA output measures dew point temperature in gases at line pressure or atmospheric pressure.

The MM300 mounts directly in the gas stream for applications including glove boxes, environmental chambers and test chambers.

The optional monitors provide many additional functions including alarm set points and 4-20mA re-transmission and provides the power for the current loop.

Can be applied in:
Industrial gases (as a purity check)

Gas :  Moisture

Application :  Industrial Gas, Intrinsically Safe

Measurement range :  -100°C to +20°C (-148°F to 68°F) Dew Point

Technology :  Aluminium oxide

Accuracy :  ±2°C (±3.6°F) Dew Point

Response Time :  90% of reading (T95) less than 5 minutes (dry to wet)

Ingress Protection :  IP66, Nema 4X

Gas :  Moisture

Application :  Industrial Gas, Intrinsically Safe

Measurement range :  -100°C to +20°C (-148°F to 68°F) Dew Point

Technology :  Aluminium oxide

Accuracy :  ±2°C (±3.6°F) Dew Point

Response Time :  90% of reading (T95) less than 5 minutes (dry to wet)

Ingress Protection :  IP66, Nema 4X

Features & Benefits

Measurement range from -100°C to +20°C (-148°F to 68°F) dew point

IP66 (NEMA 4) Protection

Fast response

Temperature compensated over operating temperature range

Two wire loop powered

Optional easy to read monitor with bright LED display eliminates reading errors

Optional remote monitoring

Optional intrinsically safe transducer

Optional wall mounted sample system

Calibration traceable to NIST