The TQC Sheen Impact Test will quickly and accurately determine the impact resistivity and flexibility of most coatings.
Description
Specifications
Documents
Options & Accessories
Brought to you by TQC Sheen, our specialist coatings inspection company, this robust impact tester for paint is relied upon across coating laboratories.
The TQC Sheen Impact Test is a dual scale impact testing device that will help you to finesse your paint production, surface finishing and powder coating applications.
When you need assurance that the distance between each impact always meets a standard, look no further than our impact tester. For this purpose we have built a spirit-level into the device for complete confidence.
SP1880: Impact test according to ISO 6272-2 / ASTM D2794
Impact tester with which indirect impact tests can be performed according to ISO 6272-2 / ASTM D2794
Content: base plate assembly, guide tube, release collar, punch Ø12,7 mm , punch Ø15,9 mm, weight 1 kg, die
Ø16,3 mm. Max test panel thickness: 4,5 mm
SP1890: Impact test according to ISO 6272-1
Impact tester with which direct impact tests can be performed according to ISO 6272-1
Content: base plate assembly, guide tube, release collar, clamp device, ball Ø20 mm, die 27mm, weight 1000 gr
Max. test panel thickness: 1,25mm
SP1891: Impact test according to ISO 6272-1 / ASTM D2794 (before 1993)
Impact test with which direct impact tests can be performed acc. to ISO 6272-1 and ASTM D2794 (before 1993).
Content: base plate assembly, guide tube, release collar, clamp device, ball Ø20
mm, die 27mm, weight 1000 gr, ball Ø15,9 mm, die 16,3mm, weight 900 gr
SP1895: Impact test according to ASTM G14
Impact test with which direct impact test can be performed according to ASTM G14
Content: base plate assembly, guide tube, release collar, clamp device, punch Ø15.9
mm, weight 1.361 kg and a V-notch vise with spring clamp to hold the pipe
SP1896: Impact Test according to CSA
Our paint impact testing machine is compatible with a range of international standards including DIN/ISO 6272, ASTM D2794 and ASTM G14.
Each impact testing machine comes as a complete set (instrument and accessories) to perform a test according to the most stringent of Qualicoat, QIB and GSB accredited laboratories requirements.
We like to share our expertise at Industrial Physics. For example, why not have a look at our blog on how to assess the quality of car paints.
Below mentioned standards are a list of the possible standards. If the required standard is not listed below please contact TQC to check if adoption of this standard is possible*:
SP1880 | SP1890 | SP1891 | SP1895 | SP1896 | |
Type of Impact | Indirect | Direct | Direct | Direct | Direct |
ISO 6272-1:2002 | • | ||||
ISO 6272-2:2002 | • | ||||
ISO 6272:1993 | • | ||||
ASTM D 2794:2004 | • | ||||
ASTM G14-04 | • | ||||
JIS K 5600-5-3:1989 | • | • | |||
EN 12206-1:2004 | • | • | • | ||
EN 13523-5:2001 | • | • | |||
AAMA 2605-05 | • | • | |||
Qualicoat 2006 | • | • | |||
Qualisteelcoat 2008 | • | • | |||
Canadian Standards Association (CSA) | • |
* Conformation to a required standard depends on the impact tester type. The combination of items can change to comply with another standard.
Although it’s robust in design, our paint impact tester is a precision engineered instrument…so keep it safe from knocks and drops! Here’s some simple advice on how to keep it in the best condition possible for years to come:
Always clean the paint impact testing device after use with a soft, dry cloth
Never use abrasive cleaning methods such as wire brushes, abrasive paper or aggressive cleaning agents.
Safety precautions
Keep fingers and other body parts clear when performing a test.
Impact test according to ISO 6272-2 / ASTM D2794
Impact tester with which indirect impact tests can be performed according to ISO 6272-2 / ASTM D2794
Content: base plate assembly, guide tube, release collar, punch Ø12,7 mm , punch Ø15,9 mm, weight 1 kg, die
Ø16,3 mm. Max test panel thickness: 4,5 mm
TQC Impact Test according to ISO 6272-1Type: Direct Impact Tester Content: Base plate assembly, guide tube, release collar, clamp device, ball Ø20 mm, die 27mm, weight 1 kg. Max. test panel thickness: 1,25mm
TQC Impact Test according to ISO 6272-1 and ASTM D2794 (before 1993)Type: Direct Impact Tester Content: Base plate assembly, guide tube, release collar, clamp device, ball Ø20 mm, die 27mm, weight 1 kg, ball Ø15.9 mm, die 16.3mm, weight 0.9 kg
TQC Impact Test according to ASTM G14 Type: Direct Impact Tester Content: Base plate assembly, guide tube, release collar, punch Ø15.9 mm, weight 1.361 kg and a V-notch vise with spring clamp to hold the pipe
TQC Impact Test according to CSA
Type: indirect impact tester
Content: base plate assembly, guide tube, release collar,
Punch and oslash: 12.7mm
Spare punch, ISO
SKU: SP1855
Spare punch, ASTM
SKU: SP1856
Die, ISO
SKU: SP1860
Die, ASTM
SKU: SP1861
Extra heavy weight 2 Kg, ISO
SKU: SP1866
Type: indirect impact tester
Content: base plate assembly, guide tube, release collar,
Punch and oslash: 12.7mm
Inbuilt spirit level for high accuracy
Complies with several international standards including ASTM
A dual scale impact tester
Precision engineered