The TQC Impact Test is used to determine the impact resistivity and flexibility of coatings. The dual scale instrument is equipped with a special guidance which assures that the distance between each impact is always according to the standard. For correct positioning a spirit-level is built-in. Each Impact test comes as a complete set (instrument and accessories) to perform a test according DIN/ISO 6272, ASTM D2794 and ASTM G14
Mandatory test in Qualicoat, QIB and GSB accredited laboratories.
Below mentioned standards are a list of the possible standards. If the required standard is not listed below please contact TQC to check if adoption of this standard is possible*:
SP1880 | SP1890 | SP1891 | SP1895 | SP1896 | |
Type of Impact | Indirect | Direct | Direct | Direct | Direct |
ISO 6272-1:2002 | • | ||||
ISO 6272-2:2002 | • | ||||
ISO 6272:1993 | • | ||||
ASTM D 2794:2004 | • | ||||
ASTM G14-04 | • | ||||
JIS K 5600-5-3:1989 | • | • | |||
EN 12206-1:2004 | • | • | • | ||
EN 13523-5:2001 | • | • | |||
AAMA 2605-05 | • | • | |||
Qualicoat 2006 | • | • | |||
Qualisteelcoat 2008 | • | • | |||
Canadian Standards Association (CSA) | • |
* Conformation to a required standard depends on the impact tester type. The combination of items can change to comply with another standard.
TQC Impact Test according to ISO 6272-1Type: Direct Impact TesterContent: Base plate assembly, guide tube, release collar, clamp device, ball Ø20 mm, die 27mm, weight 1 kg. Max. test panel thickness: 1,25mm
TQC Impact Test according to ISO 6272-1 and ASTM D2794 (before 1993)Type: Direct Impact TesterContent: Base plate assembly, guide tube, release collar, clamp device, ball Ø20 mm, die 27mm, weight 1 kg, ball Ø15.9 mm, die 16.3mm, weight 0.9 kg
TQC Impact Test according to ASTM G14Type: Direct Impact TesterContent: Base plate assembly, guide tube, release collar, punch Ø15.9 mm, weight 1.361 kg and a V-notch vise with spring clamp to hold the pipe
TQC Impact Test according to CSA
Type: Indirect Impact Tester
Content: Base plate assembly, guide tube, release collar,
punch & Oslash: 12.7 mm , punch Ø
Type: Indirect Impact Tester
Content: Base plate assembly, guide tube, release collar,
punch & Oslash: 12.7 mm , punch Ø