Product Categories Beverage Testing EquipmentEnvironmental ChambersEnvironmental Testing EquipmentFilm ApplicatorsFlexible Packaging Testing EquipmentInks and Coating Inspection EquipmentMaterial Testing EquipmentMetal Packaging Testing EquipmentMicrometersOxygen Process Testing EquipmentPaper and Pulp Testing EquipmentPhysical Property Measurement EquipmentProfile/Plus Range by TechnidyneSalt Fog TestersTest/Plus Range by TechnidyneUniversal Testing Machines
Brands C&W Specialist ProductsCMC-KUHNKE ProductsEagle Vision Systems ProductsMessmer Büchel ProductsOxySense ProductsQuality By Vision ProductsRay-Ran ProductsSteinfurth ProductsSystech Illinois ProductsTechnidyne ProductsTesting Machines Inc ProductsTM Electronics ProductsTQC Sheen ProductsUnited Testing Products
Back to Product Search
Back to Product Search
Products  > Ray-Ran 3 & 6 Station Heat Distortion & Vicat Softening Point Apparatus

Ray-Ran 3 & 6 Station Heat Distortion & Vicat Softening Point Apparatus

The HDT/Vicat Apparatus is used to detemine the Deflection and softening point characteristics of all types of thermo plastic specimens.

In order to request a quote, arrange a service or make an inquiry about this product you must select modifiers above.

Description

Designed and built to cover multiple international testing standards, it utilizes microprocessor technology to accurately determine the deflection and softening point characteristics of all thermo-plastic test specimens.  The 3 & 6 station devices will test three or six samples simultaneously.

The simple manually operated raise and lower function of the test stations ensure easy access to the test sample supports for sample loading and retrieval before and after each test. Each test station is fitted with a PT100 platinum resistance thermometer which accurately records the temperature next to the sample under test to 0.1°C and an electronic displacement transducer which measures the sample displacement to 0.01mm as standard or to 0.001mm as an option. The built-in LCD provides simple on-screen instructions reducing user error. Test parameters are easily selected using the keypad. A simple data selection process and yes/no prompts make the operating procedure very simple to undertake.

The microprocessor’s temperature control function ensures the ramping rates of either 50°C/h or 120°C/h are kept within the specified test standard requirements as well as performing non-standard ramp rates to customers own specific needs. Test temperatures of 300°C are easily achieved and to ensure optimum safety at higher temperatures, the Nitrogen Blanket option is recommended. The methods of testing available on the apparatus are: HDT – Heat deflection / distortion test. Testing is carried out in accordance with the ISO75 (parts 1, 2 and 3) and ASTMD648 Test Standards.

For this test, a required fibre stress of 0.45, 1.8, or 8.00 MPa is easily selected. Custom fibre stresses can also be managed by the microprocessor if required. The HDT span supports of 100mm or 64mm are easily adjusted on each tool station to suite your testing method of Flat wise or Edgewise sample testing. Each machine is supplied with HDT test nibs with 3mm radius which are easily attached to the load displacement rods for testing in accordance with relevant international test standards. Vicat (VST) – Softening point test. Testing is carried out in accordance with the ISO306 and ASTMD1525 Test Standards.

For this test, penetration loads are easily selected via the microprocessor for use with the single loading weights of 10 N and 50N. The supplied cylindrical indenter test nib with 1mm² surface area is attached to the load displacement rod for sample testing in accordance with relevant testing standard. The self-calibration feature of the apparatus ensures that the test results remain accurate. Unique calibration plugs are supplied with each machine which simply plug into the PRT socket for you to carry out the calibration procedure.

Test results are downloaded to the supplied file capture software via the USB or Ethernet connector and are displayed in tabular format. Results can also be saved as .CSV files.

Optional Ancillaries:
Binary HDT Test Weights (1 set required per station)
1.00Kg Vicat Test Weight (1 required per station)
5.00Kg Vicat Test Weight (1 required per station)
Displacement Transducer 0.001mm
Light Weight Load rods to test to .45 MPa
Heat Transfer Medium 20 litres
Nitrogen Blanket
Water Chiller unit

Product Video

More Product Videos

Interested in this product?

Please select product variables here Make an Inquiry Request a Quote Request a Quote

Do you own this product?

Please select product variables here Get Product Support Get Product Support Arrange a Service Arrange a Service
Can't find what you are looking for?
Can't find what you are looking for?