Knowledge Base

Articles

Gurley Porosity Testing and Inline Air Permeability Monitoring Explained

Paper and board manufacturers need to know how porous their sheet is at two different points: while it is being made, and after it is made. This piece explains both approaches, why they matter together, and how the results relate to each other.

Overview

Porosity describes how open or closed the internal fiber structure of a sheet is. It is not a surface property alone; it reflects how the fibers, fines, and fillers have bonded together during formation, pressing, and drying.

Two measurement approaches are used in practice:

  • Inline air permeability monitoring, which measures porosity continuously on the running web during production.
  • Gurley porosity testing, an offline lab method standardized under TAPPI T460 and ISO 5636-5, which measures porosity on a discrete sample after the sheet has been made.

Both methods measure the same underlying property, air permeance, but they answer different questions. Inline monitoring asks “is the process stable right now?” Offline lab testing asks “does this finished sheet meet specification?”

Why Porosity Matters in Production

Porosity is not tested for its own sake. It is a proxy for properties that matter commercially:

  • Porosity affects how ink sets on the sheet. Too porous, and ink strikes through or dries unevenly. Too closed, and ink sits on the surface without proper anchorage.
  • Coating holdout. Coatings and sizing agents behave differently depending on how much they penetrate the sheet. Consistent porosity means consistent coating weight and appearance.
  • Barrier and converting performance. For packaging and specialty grades, porosity relates directly to barrier properties and how the sheet behaves during converting, laminating, or filling operations.
  • Refining efficiency. Porosity correlates closely with the degree of fiber refining. Monitoring it in real time lets operators adjust refining energy without over- or under-processing the pulp.

Because porosity connects to so many downstream outcomes, catching drift early, at the point of production, has a direct cost benefit: fewer off-spec reels, less rework, and fewer customer complaints.

Equipment and Setup: Inline Monitoring

Inline air permeability monitoring uses a sensor mounted on or near the paper machine that samples the moving web directly. A device such as the ACA Permi online porosity analyzer continuously measures air permeability across the sheet and reports results back to the mill’s process control system, via OPC DA and OPC UA data bus outputs.

The instrument supports a wide measurement range: 0.02 to 12,000 l/m2/s air flow, 0.02 to 6,000 Gurley seconds, 1 to 50,000 ml/min Bendtsen, and 1 to 40,000 Coresta units, making it suitable across a broad range of paper and board grades.

Setup considerations for inline monitoring include:

  • Scanner configuration. Sensor width and scanning speed are selected according to the machine and grade being run.
  • The system uses a single calibration curve per measurement system, with up to four grade recipes each supported by a dedicated calibration curve.
  • Sensors that draw air through the sheet require periodic filter replacement (typically every four to eight weeks, depending on the operating environment) to maintain accuracy.
  • Self-cleaning cycles. Includes an automatic self-cleaning cycle on an adjustable timer, reducing the maintenance burden and helping sustain measurement accuracy between service visits.

Equipment and Setup: Offline Gurley Testing

The Gurley method uses a benchtop instrument built around a weighted, freely floating cylinder inside an outer cylinder, sealed with oil or a similar medium. A sample of paper or board is clamped over the opening at the base of the instrument.

Key setup points:

  • The Gurley method is suitable for papers and boards with air permeance roughly between 0.1 and 100 micrometers per pascal-second. It is not suitable for materials with rough surfaces that cannot be clamped tightly enough to prevent leakage around the edge of the sample.
  • Automated versions, such as the Technidyne PROFILE/Plus Porosity range, combine porosity measurement with roughness testing (Sheffield or Bendtsen) in a single device, returning results in under ten seconds per reading.
  • Calibrated air flow restrictors are used periodically to verify the instrument’s flow measurement against a known reference.

Test Procedure (Offline Gurley Method)

  1. Condition the sample. Paper and board are sensitive to humidity and temperature, so samples should be conditioned to standard laboratory atmosphere before testing.
  2. Clamp the sample. The test piece is secured in the instrument so no air can leak around the edges.
  3. Apply air pressure. A fixed volume of air, driven by the weight of the floating cylinder, is forced through the sample.
  4. Measure the time. The instrument records the time taken for the set air volume to pass through the sample area. This is reported in Gurley seconds.
  5. Repeat and average. Multiple readings are taken across the sample and across the reel or sheet to account for natural variation in formation.

Interpreting Results

  • Higher Gurley seconds mean the sheet is denser and less permeable; air takes longer to pass through.
  • Lower Gurley seconds mean the sheet is more open and porous.
  • Inline results (typically reported in permeability units appropriate to the sensor, rather than Gurley seconds directly) should track consistently with offline lab results over time. If inline and offline data diverge, this is usually a sign of a calibration issue, a sampling location difference, or a genuine cross-sheet variation that the inline sensor is catching but the lab sample missed.

Common Errors and Best Practices

  • Leakage around the clamp is the most common source of error in offline Gurley testing, particularly on rough or uneven samples. A poor seal reads as falsely high porosity.
  • Inconsistent sample conditioning (humidity, temperature) will shift readings independent of the sheet’s actual structure.
  • Infrequent inline sensor maintenance (dirty filters, uncalibrated flow paths) leads to drift that can go unnoticed until offline lab results disagree significantly with inline data.
  • Relying on a single reading. Porosity varies across the width and length of a sheet. Both inline scanning and multi-point offline sampling exist specifically to capture this variation rather than assume uniformity.

Why This Matters for Quality and Process Control

Used together, inline and offline porosity measurement give mills a closed loop: real-time process control on the machine, backed by a standardized, auditable lab result for quality sign-off and customer specification. This combination protects product consistency and reduces the risk of off-spec production reaching the customer, supporting Industrial Physics’ purpose of protecting the integrity of our customers’ brands and products.

Was this useful?

FAQs

  • Inline testing measures air permeability continuously on the running paper machine, supporting real-time process adjustments. Offline testing, typically the Gurley method under TAPPI T460 or ISO 5636-5, measures a cut sample in the lab to confirm the finished sheet meets specification.

  • Gurley seconds record the time taken for a fixed volume of air to pass through a fixed area of sample under a set pressure. A higher number means a denser, less permeable sheet; a lower number means a more open, porous sheet.

  • Porosity controls how ink, coatings, and sizing agents interact with the sheet surface. Uneven porosity leads to uneven ink absorption, coating weight, or gloss, which shows up as visible print or coating defects.

  • No. The Gurley method is suitable for air permeance roughly between 0.1 and 100 micrometers per pascal-second. It is not suitable for rough-surfaced materials that cannot be clamped tightly enough to prevent air leakage around the sample edge.

  • Filters on inline air permeability sensors typically need replacing every four to eight weeks, depending on the operating environment, to maintain measurement accuracy.

Related Articles