Knowledge Base

Articles

Color Measurement in Can Making – Key Terms Explained

A reference glossary for quality, R&D, and operations professionals working in metal packaging and rigid can making.

Hue The fundamental color perceived by the eye – for example, red, blue, or green. One of three attributes used to define and measure color in the can-making industry.

Chroma The vividness or saturation of a color – how pure or intense it appears. A high-chroma red is vivid and bright; a low-chroma red appears dull or washed out. Also referred to as saturation.

Lightness (L*) A measure of how light or dark a color is, on a scale from 0 (black) to 100 (white). One of the three axes in the CIELAB color scale.

Spectrophotometer An instrument that measures color by analyzing the light reflected from a surface and converting it into standardized numerical values. In can making, spectrophotometers are used to compare the decorated color of a can against a brand-approved standard. The Torus Z345 integrates an X-Rite spectrophotometer into an automated inspection system designed specifically for beverage cans.

Illuminated Assessment Cabinet A controlled viewing environment used for visual color assessment. By providing standardized light sources – such as D65 daylight simulation, TL84, UV, and incandescent – it eliminates the influence of ambient lighting on color perception, ensuring consistent visual comparisons between production samples and color standards. The TQC Sheen ColourBox is an illuminated assessment cabinet used in can making and other metal packaging applications. 

Metamerism A phenomenon where two colors appear to match under one light source but look different under another. Relevant in can making because decorated cans are viewed under varying lighting conditions – from the production facility to the retail shelf. Illuminated assessment cabinets with multiple light sources, such as the TQC Sheen ColourBox, help identify metamerism risk during quality inspection. 

CIELAB (L*a*b*) A standardized color scale defined by the International Commission on Illumination (CIE). Describes color in three dimensions: lightness (L*), red-green axis (a*), and blue-yellow axis (b*). Widely used in the beverage can industry for color specification and quality control. 

CIELCH (L*C*h°) An alternative CIE color scale that expresses color in terms of lightness (L*), chroma (C*), and hue angle (h°). Often considered more intuitive than CIELAB for communicating color differences. 

Delta E (ΔE) The total numerical difference between a measured color value and the target standard. A ΔE of 0 indicates a perfect match; higher values indicate greater deviation. Tolerances are typically set by the brand owner and used to determine pass/fail status. 

Color Standard A brand-approved reference color, expressed as numerical values in a standardized color scale (e.g. CIELAB). Used as the benchmark against which all production samples are measured. 

Color Tolerance The acceptable range of deviation from a color standard, typically expressed as a ΔE value. Samples that fall within tolerance pass inspection; those outside fail. 

Linescan Camera A type of camera used in automated inspection systems that captures image data one line at a time as an object passes beneath it. Used in the Torus Z345 to create a full 360° flattened image of a decorated can’s surface. 

Was this useful?

FAQs

  • Automated color inspection systems eliminate operator influence from the measurement process. Systems such as the Torus Z345 Automatic Color Inspection Gauge use a linescan camera to capture a full 360° image of the decorated can, orient it precisely against a master image, and then present it to an integrated X-Rite spectrophotometer at pre-defined measurement points. This ensures that every can is measured at exactly the same position, delivering accurate, repeatable results at scale – and giving quality teams the data confidence they need to protect brand color standards. For a broader view of what’s possible in rigid can making, explore our full range of test and measurement solutions for the industry. 

  • Color on decorated cans is measured using a spectrophotometer – an instrument that analyzes the light reflected from the can’s surface and converts it into numerical values using standardized CIE color scales (typically CIELAB or CIELCH). These values are compared against a brand-approved color standard, with tolerances defining whether the can passes or fails inspection. The total numerical difference between the measured color and the target is expressed as Delta E (ΔE). The Torus Z345 automates this process for decorated aluminum and steel beverage cans, delivering repeatable, operator-independent results. 

  • Color inspection in can making typically follows two stages. The first is visual assessment under controlled, standardized lighting conditions – using an illuminated assessment cabinet such as the TQC Sheen ColourBox. This removes the distorting influence of ambient lighting and allows operators to compare production samples against color standards across multiple light sources, including daylight simulation (D65), fluorescent, and UV. The second stage is instrument-based measurement, using a spectrophotometer to generate objective numerical color data, compared against a brand-approved standard with defined tolerances. Together, these two stages provide both human judgement and quantifiable data confidence. 

  • Color consistency refers to the ability to reproduce a brand’s approved colors accurately across every decorated can – regardless of production shift, line, or site. It matters because color is one of the first things a consumer notices on shelf, and even subtle variation can be visible when multiple cans are displayed together. For brand owners, inconsistent color can undermine consumer confidence and brand recognition. For can makers, it can result in costly production rejections and strained customer relationships. Learn more about the role of precision in metal packaging testing. 

  • Metamerism is a phenomenon where two colors appear to match under one light source but look noticeably different under another. In can making, this is a practical quality risk – a can that looks correct under workshop lighting may appear off-color under the fluorescent lighting of a supermarket. Illuminated assessment cabinets, such as the TQC Sheen ColourBox, address this by enabling visual assessment under multiple standardized light sources, helping operators identify metamerism before cans reach the end of the line. 

Related Articles