{"id":289800,"date":"2025-01-23T06:13:59","date_gmt":"2025-01-23T10:13:59","guid":{"rendered":""},"modified":"2026-07-07T04:34:05","modified_gmt":"2026-07-07T08:34:05","slug":"astm-e834-11-es","status":"publish","type":"standards","link":"https:\/\/industrialphysics.com\/es\/estandares\/astm-e834-11-es\/","title":{"rendered":"ASTM E834-11"},"content":{"rendered":"<h2>Presentamos ASTM E834-11 &#8211; Industrial Physics<\/h2>\n<p><span data-contrast=\"none\">LA NORMA ASTM E834-11 <\/span><span data-contrast=\"auto\">es una norma<\/span><span data-contrast=\"none\"> internacional ASTM<\/span><span data-contrast=\"auto\"> internacional ASTM para medir la microdureza <\/span><span data-contrast=\"none\">microdureza knoop y vickers<\/span><span data-contrast=\"auto\"> de los materiales met\u00e1licos.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Cuando necesitas saber lo dura que es una muestra -y lo bien que resistir\u00e1 la penetraci\u00f3n-. <\/span><span data-contrast=\"none\">ensayo de microdureza<\/span><span data-contrast=\"auto\"> es la elecci\u00f3n obvia.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p><span data-contrast=\"none\">Pruebas de microdureza<\/span><span data-contrast=\"auto\">  es un m\u00e9todo para determinar la dureza o resistencia a la deformaci\u00f3n de un material. El <\/span><span data-contrast=\"none\">LA NORMA ASTM E834-11<\/span><span data-contrast=\"auto\"> describe un enfoque eficaz y fiable para <\/span><span data-contrast=\"none\">ensayo de microdureza knoop y vickers.<\/span><span data-contrast=\"auto\"> <\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<h2>\u00bfQu\u00e9 es la prueba de dureza Knoop seg\u00fan las normas ASTM?<\/h2>\n<p><span data-contrast=\"none\">Prueba de dureza Knoop  <\/span><span data-contrast=\"auto\">utiliza un penetrador alargado de forma rectangular. Se empuja hacia la superficie de una muestra para producir una muesca que luego se mide. A diferencia de la  <\/span><span data-contrast=\"none\">m\u00e9todo de ensayo vickers<\/span><span data-contrast=\"auto\">la <\/span><span data-contrast=\"none\">ensayo knoop <\/span><span data-contrast=\"auto\">utiliza s\u00f3lo el eje largo al calcular la indentaci\u00f3n como indicador de dureza.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">En <\/span><span data-contrast=\"none\">Prueba de nudos ASTM E834-11 <\/span> <span data-contrast=\"auto\">a menudo se desempe\u00f1a con cargas m\u00e1s ligeras. La forma de la  <\/span><span data-contrast=\"none\">prueba de dureza<\/span><span data-contrast=\"auto\">  Muestra\/Probeta significa que es adecuada para muestras que necesitan que las muescas est\u00e9n muy juntas, o en el borde de una muestra. Tambi\u00e9n puede ofrecer mayores niveles de precisi\u00f3n que la  <\/span><span data-contrast=\"none\">pruebas vickers<\/span><span data-contrast=\"auto\">  ya que la diagonal longitudinal del penetrador es mayor. Preparaci\u00f3n cuidadosa de la muestra para<\/span> <span data-contrast=\"none\"> normas ASTM <\/span><span data-contrast=\"auto\">para garantizar la exactitud de los resultados.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<h2>\u00bfQu\u00e9 es la prueba de dureza Vickers seg\u00fan las normas ASTM?<\/h2>\n<p><span data-contrast=\"auto\">El <\/span><span data-contrast=\"none\">prueba de dureza vickers<\/span><span data-contrast=\"auto\"> es similar al <\/span><span data-contrast=\"none\">prueba knoop<\/span><span data-contrast=\"auto\">  pero utiliza un penetrador de forma diferente. El<\/span><span data-contrast=\"none\">  penetrador vickers<\/span><span data-contrast=\"auto\">  tiene forma de pir\u00e1mide en cuclillas y suele presionarse sobre la superficie del material durante 10 segundos. La cantidad de fuerza utilizada es una cantidad predeterminada y var\u00eda seg\u00fan los materiales que se prueban.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Una vez transcurrido el tiempo, la muesca dejada en la muestra se analiza \u00f3pticamente para medir las longitudes de las diagonales. Estos se utilizan luego para calcular el tama\u00f1o de la impresi\u00f3n.  <\/span><span data-contrast=\"none\">El ensayo Vickers<\/span><span data-contrast=\"auto\"> no es adecuado para espesores de revestimiento inferiores a 60 micras.<\/span><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p data-ccp-border-between=\"0px none #000000\" data-ccp-padding-between=\"0px\"><span data-contrast=\"auto\">Para m\u00e1s informaci\u00f3n sobre <\/span><span data-contrast=\"none\">ensayos de microdureza<\/span><span data-contrast=\"auto\">visita nuestro blog <\/span><a href=\"https:\/\/industrialphysics.com\/es\/base-de-conocimientos\/articulos\/explicacion-de-las-pruebas-de-microdureza-pruebas-de-vickers-y-knoop\/\"><span data-contrast=\"none\">haciendo clic aqu\u00ed.<\/span><\/a><span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386,\"335572071\":0,\"335572072\":0,\"335572073\":0,\"335572075\":0,\"335572076\":0,\"335572077\":0,\"335572079\":0,\"335572080\":0,\"335572081\":0,\"335572083\":0,\"335572084\":0,\"335572085\":0,\"335572087\":0,\"335572088\":0,\"335572089\":0,\"469789798\":\"none\",\"469789802\":\"none\",\"469789806\":\"none\",\"469789810\":\"none\",\"469789814\":\"none\"}\"> <\/span><\/p>\n<h2>Equipo de prueba ASTM E834-11<\/h2>\n<p><span data-contrast=\"auto\">Entonces, \u00bfc\u00f3mo puede Industrial Physics mejorar su <\/span><span data-contrast=\"none\">ASTM E834-11 <\/span><span data-contrast=\"auto\">pruebas? <\/span> <span data-ccp-props=\"{\"201341983\":0,\"335559738\":280,\"335559739\":280,\"335559740\":386}\"> <\/span><\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/es\/producto\/tru-blue-micro-vt\/\"><b><span data-contrast=\"none\">Tru-Blue mVT (MicroVT)<\/span><\/b><\/a><span data-ccp-props=\"{\"201341983\":0,\"335559740\":276}\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Una prueba de microdureza Semiautomatizada <\/span><span data-contrast=\"none\">ensayo de microdureza<\/span><span data-contrast=\"auto\">  sistema. Mide valores de dureza en las escalas vickers (HV) y knoop (HK) desde 10 g hasta 1000 g (1 kg).  <\/span><span data-ccp-props=\"{\"201341983\":0,\"335559740\":276}\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Nuestra electr\u00f3nica de \u00faltima generaci\u00f3n y pantallas \u00f3pticas de alta calidad hacen que la ejecuci\u00f3n de las pruebas sea r\u00e1pida y sencilla. Y nuestra  <\/span><span data-contrast=\"none\">dispositivos de ensayo de microdureza<\/span><span data-contrast=\"auto\"> te ofrecen resultados precisos y repetibles. <\/span> <span data-ccp-props=\"{\"201341983\":0,\"335559740\":276}\"> <\/span><\/p>\n<p><em><b>Tu socio global de pruebas y Mediciones para <\/b><b>ASTM E834-11<\/b> <\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Presentamos ASTM E834-11 &#8211; Industrial Physics LA NORMA ASTM E834-11 es una norma internacional ASTM internacional ASTM para medir la microdureza microdureza knoop y vickers de &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/industrialphysics.com\/es\/estandares\/astm-e834-11-es\/\" class=\"more-link\">Seguir leyendo<span class=\"screen-reader-text\"> \u00abASTM E834-11\u00bb<\/span><\/a><\/p>\n","protected":false},"author":148,"featured_media":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"standards_categories":[11815,11818],"class_list":["post-289800","standards","type-standards","status-publish","hentry","standards_categories-industry-standards-es","standards_categories-international-standards-es","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Physics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Physics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@IndustrialPhys\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\n\t    \"@context\": \"https:\\\/\\\/schema.org\",\n\t    \"@graph\": [\n\t        {\n\t            \"@type\": \"CollectionPage\",\n\t            \"@id\": null,\n\t            \"url\": \"\",\n\t            \"name\": \"\",\n\t            \"isPartOf\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#website\"\n\t            },\n\t            \"inLanguage\": \"es\"\n\t        },\n\t        {\n\t            \"@type\": \"WebSite\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#website\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"description\": \"\",\n\t            \"publisher\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#organization\"\n\t            },\n\t            \"potentialAction\": [\n\t                {\n\t                    \"@type\": \"SearchAction\",\n\t                    \"target\": {\n\t                        \"@type\": \"EntryPoint\",\n\t                        \"urlTemplate\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/?s={search_term_string}\"\n\t                    },\n\t                    \"query-input\": {\n\t                        \"@type\": \"PropertyValueSpecification\",\n\t                        \"valueRequired\": true,\n\t                        \"valueName\": \"search_term_string\"\n\t                    }\n\t                }\n\t            ],\n\t            \"inLanguage\": \"es\"\n\t        },\n\t        {\n\t            \"@type\": \"Organization\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#organization\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/\",\n\t            \"logo\": {\n\t                \"@type\": \"ImageObject\",\n\t                \"inLanguage\": \"es\",\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\n\t                \"url\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"contentUrl\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"width\": 196,\n\t                \"height\": 196,\n\t                \"caption\": \"Industrial Physics\"\n\t            },\n\t            \"image\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"\n\t            },\n\t            \"sameAs\": [\n\t                \"https:\\\/\\\/x.com\\\/IndustrialPhys\",\n\t                \"https:\\\/\\\/www.linkedin.com\\\/company\\\/industrial-physics\\\/\",\n\t                \"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCrx-7K2sYE4ppkqkhAbkO1A\"\n\t            ]\n\t        }\n\t    ]\n\t}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Physics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"\/","og_locale":"es_ES","og_type":"article","og_site_name":"Industrial Physics","twitter_card":"summary_large_image","twitter_site":"@IndustrialPhys","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":null,"url":"","name":"","isPartOf":{"@id":"https:\/\/industrialphysics.com\/es\/#website"},"inLanguage":"es"},{"@type":"WebSite","@id":"https:\/\/industrialphysics.com\/es\/#website","url":"https:\/\/industrialphysics.com\/es\/","name":"Industrial Physics","description":"","publisher":{"@id":"https:\/\/industrialphysics.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/industrialphysics.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/industrialphysics.com\/es\/#organization","name":"Industrial Physics","url":"https:\/\/industrialphysics.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/industrialphysics.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","contentUrl":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","width":196,"height":196,"caption":"Industrial Physics"},"image":{"@id":"https:\/\/industrialphysics.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/IndustrialPhys","https:\/\/www.linkedin.com\/company\/industrial-physics\/","https:\/\/www.youtube.com\/channel\/UCrx-7K2sYE4ppkqkhAbkO1A"]}]}},"_links":{"self":[{"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/standards\/289800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/standards"}],"about":[{"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/types\/standards"}],"author":[{"embeddable":true,"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":2,"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/standards\/289800\/revisions"}],"predecessor-version":[{"id":490984,"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/standards\/289800\/revisions\/490984"}],"wp:attachment":[{"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/media?parent=289800"}],"wp:term":[{"taxonomy":"standards_categories","embeddable":true,"href":"https:\/\/industrialphysics.com\/es\/wp-json\/wp\/v2\/standards_categories?post=289800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}