{"id":291102,"date":"2025-01-23T06:13:59","date_gmt":"2025-01-23T10:13:59","guid":{"rendered":""},"modified":"2026-10-21T08:02:45","modified_gmt":"2026-10-21T12:02:45","slug":"astm-d1729-de","status":"publish","type":"standards","link":"https:\/\/industrialphysics.com\/de\/standards\/astm-d1729-de\/","title":{"rendered":"ASTM D1729"},"content":{"rendered":"<h2>Wir stellen vor: ASTM D1729 \u2013 Industrial Physics<\/h2>\n<p><span data-contrast=\"none\">ASTM D1729<\/span> <span data-contrast=\"auto\">ist eine<\/span> <span data-contrast=\"none\">internationale ASTM-<\/span> <span data-contrast=\"auto\">Standardspezifikation f\u00fcr die visuelle Beurteilung von Farben und Farbunterschieden diffus beleuchteter undurchsichtiger Materialien.<\/span> <span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Es handelt sich um einen<\/span> <span data-contrast=\"none\">ASTM-Ansatz<\/span> , der die f\u00fcr die <span data-contrast=\"none\">Farb\u00fcbereinstimmungspr\u00fcfung<\/span> <span data-contrast=\"auto\">erforderlichen Ger\u00e4te und Verfahren spezifiziert<\/span> . <span data-contrast=\"auto\">Es handelt sich um eine Beobachtung zur Farbmessung, die Beurteilungen von Beobachtern erfordert, die mindestens \u00fcber ein Minimum an normalem Farbsehen verf\u00fcgen.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p>Wenn Sie die Farbe und <span data-contrast=\"none\">Farbunterschiede<\/span> <span data-contrast=\"auto\">pr\u00fcfen<\/span><span data-contrast=\"auto\"> F\u00fcr Materialien wie Metallic- und Perlglanzlacke ist eine starke Beleuchtung erforderlich. Eine Beleuchtung, die einer geometrischen Simulation von direktem Sonnenlicht nahekommt. Denn durch gerichtete Beleuchtung k\u00f6nnen Sie das Glitzern (Glitzern) und den Goniochromatismus solcher Materialien beobachten.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<h2><b><span data-contrast=\"auto\">Der<\/span><\/b> <b><span data-contrast=\"none\">ASTM D1729-Prozess<\/span><\/b><\/h2>\n<p><span data-contrast=\"auto\">Beim Testen nach<\/span> <span data-contrast=\"none\">ASTM D1729<\/span> <span data-contrast=\"auto\">wird \u00fcblicherweise ein<\/span> <span data-contrast=\"none\">Farbmessger\u00e4t<\/span> verwendet<span data-contrast=\"auto\"> Standards, Farb\u00fcbereinstimmungen k\u00f6nnen aber auch visuell \u00fcberpr\u00fcft werden. Die Standardisierung der visuellen Pr\u00fcfung hat die Einheitlichkeit der Produkte und die Genauigkeit der Farb\u00fcbereinstimmungen erheblich verbessert.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Sowie kritische<\/span> <span data-contrast=\"none\">Farbanpassung<\/span> <span data-contrast=\"auto\">an<\/span> <span data-contrast=\"none\">ASTM D1729<\/span> <span data-contrast=\"auto\">Dieser Ansatz kann Ihnen dabei helfen, eine Farbe auszuw\u00e4hlen oder zu genehmigen. Diese Praxis wird in der Industrie h\u00e4ufig verwendet, um:<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<ul>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"auto\">W\u00e4hlen Sie Farben<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"auto\">Zeigen Sie die Reproduzierbarkeit einer Farbe an<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"auto\">\u00dcberpr\u00fcfen Sie eingehende Materialien<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span data-contrast=\"auto\">\u00dcberwachen Sie Farbproduktionsprozesse<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"5\" data-aria-level=\"1\"><span data-contrast=\"auto\">\u00dcberpr\u00fcfen Sie die fertige Ware<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">Eine visuelle<\/span> <span data-contrast=\"none\">Farbpr\u00fcfung<\/span> <span data-contrast=\"auto\">ist wichtig, wenn das gepr\u00fcfte Produkt nicht aus dem gleichen Material besteht wie der Farbstandard, mit dem es verglichen wird.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<h2><b><span data-contrast=\"auto\">Einhaltung<\/span><\/b> <b><span data-contrast=\"none\">der ASTM D1729-Tests<\/span><\/b><span data-ccp-props=\"{\"> <\/span><\/h2>\n<p><span data-contrast=\"auto\">Es wird davon ausgegangen, dass der Beobachter der<\/span> <span data-contrast=\"none\">ASTM D1729<\/span> entspricht <span data-contrast=\"auto\">Der Test verf\u00fcgt \u00fcber ein ausgezeichnetes Farbsehen und ist in der Beobachtung und Klassifizierung von Farbunterschieden geschult und erfahren. Zum Gl\u00fcck innerhalb<\/span> <span data-contrast=\"none\">ASTM E1499<\/span> <span data-contrast=\"auto\">finden Sie Anleitungen zur Auswahl, Bewertung und Schulung von Beobachtern.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Die Beleuchtung des Experiments sollte durchschnittliches Tageslicht simulieren. Es wird empfohlen, das Leuchtmittel D65 nach CIE-Standard zu verwenden. Es handelt sich um ein h\u00e4ufig verwendetes Standardlichtmittel, das von der International Commission on Illumination (CIE) definiert wurde.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<h2><b><span data-contrast=\"none\">ASTM D1729-<\/span><\/b> <b><span data-contrast=\"auto\">Pr\u00fcfger\u00e4te<\/span><\/b><\/h2>\n<p><span data-contrast=\"auto\">Wie kann Industrial Physics Ihre<\/span> <span data-contrast=\"none\">ASTM D1729-<\/span> <span data-contrast=\"auto\">Tests verbessern?<\/span> <span data-ccp-props=\"{\"> <\/span><\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/de\/produkt\/colorbox-beleuchtete-beurteilungsschraenke\/\"><b><span data-contrast=\"none\">TQC Sheen Colorbox \u2013 beleuchtete Bewertungsschr\u00e4nke<\/span><\/b><\/a><\/p>\n<p><span data-contrast=\"auto\">Unsere<\/span> <span data-contrast=\"none\">Beleuchtungspr\u00fcfschr\u00e4nke<\/span> <span data-contrast=\"auto\">sind f\u00fcr eine genaue Farbbeurteilung konzipiert und ideal f\u00fcr<\/span> <span data-contrast=\"none\">ASTM D1729<\/span><span data-contrast=\"auto\"> testen. Benutze einen <\/span><span data-contrast=\"none\">Colorbox<\/span> <span data-contrast=\"auto\">zur Pr\u00fcfung und Farbanpassung von Tinten, Farben, Kunststoffen, Kosmetika, Textilien, Strickwaren, Lebensmitteln, Papier, Farbstoffen und anderen farbigen Materialien.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">TQC-Farbboxen bieten eine Reihe von Beleuchtungsbedingungen f\u00fcr jede visuelle Inspektion. Die vielf\u00e4ltigen, w\u00e4hlbaren Lichtquellen erm\u00f6glichen die Beurteilung von Glanz, Struktur, Besch\u00e4digungen und Metamerie. <\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Unsere Farbboxen sind in den Breiten 60 und 120 cm erh\u00e4ltlich. Sie werden mit abnehmbaren Betrachtungstischen und Laufzeitz\u00e4hlern geliefert und entsprechen den h\u00f6chsten Qualit\u00e4tsstandards. <\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><i><span data-contrast=\"auto\">Ihr globaler Partner f\u00fcr Tests und Messungen <\/span><\/i><\/b><b><i><span data-contrast=\"none\">ASTM D1729<\/span><\/i><\/b><span data-ccp-props=\"{\"> <\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wir stellen vor: ASTM D1729 \u2013 Industrial Physics ASTM D1729 ist eine internationale ASTM- Standardspezifikation f\u00fcr die visuelle Beurteilung von Farben und Farbunterschieden diffus beleuchteter undurchsichtiger &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/industrialphysics.com\/de\/standards\/astm-d1729-de\/\" class=\"more-link\"><span class=\"screen-reader-text\">\u201eASTM D1729\u201c <\/span>weiterlesen<\/a><\/p>\n","protected":false},"author":148,"featured_media":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"standards_categories":[11813,11817],"class_list":["post-291102","standards","type-standards","status-publish","hentry","standards_categories-industry-standards-de","standards_categories-international-standards-de","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Physics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Physics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@IndustrialPhys\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\n\t    \"@context\": \"https:\\\/\\\/schema.org\",\n\t    \"@graph\": [\n\t        {\n\t            \"@type\": \"CollectionPage\",\n\t            \"@id\": null,\n\t            \"url\": \"\",\n\t            \"name\": \"\",\n\t            \"isPartOf\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\"\n\t            },\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"WebSite\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"description\": \"\",\n\t            \"publisher\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\"\n\t            },\n\t            \"potentialAction\": [\n\t                {\n\t                    \"@type\": \"SearchAction\",\n\t                    \"target\": {\n\t                        \"@type\": \"EntryPoint\",\n\t                        \"urlTemplate\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/?s={search_term_string}\"\n\t                    },\n\t                    \"query-input\": {\n\t                        \"@type\": \"PropertyValueSpecification\",\n\t                        \"valueRequired\": true,\n\t                        \"valueName\": \"search_term_string\"\n\t                    }\n\t                }\n\t            ],\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"Organization\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"logo\": {\n\t                \"@type\": \"ImageObject\",\n\t                \"inLanguage\": \"de\",\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\n\t                \"url\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"contentUrl\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"width\": 196,\n\t                \"height\": 196,\n\t                \"caption\": \"Industrial Physics\"\n\t            },\n\t            \"image\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"\n\t            },\n\t            \"sameAs\": [\n\t                \"https:\\\/\\\/x.com\\\/IndustrialPhys\",\n\t                \"https:\\\/\\\/www.linkedin.com\\\/company\\\/industrial-physics\\\/\",\n\t                \"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCrx-7K2sYE4ppkqkhAbkO1A\"\n\t            ]\n\t        }\n\t    ]\n\t}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Physics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"\/","og_locale":"de_DE","og_type":"article","og_site_name":"Industrial Physics","twitter_card":"summary_large_image","twitter_site":"@IndustrialPhys","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":null,"url":"","name":"","isPartOf":{"@id":"https:\/\/industrialphysics.com\/de\/#website"},"inLanguage":"de"},{"@type":"WebSite","@id":"https:\/\/industrialphysics.com\/de\/#website","url":"https:\/\/industrialphysics.com\/de\/","name":"Industrial Physics","description":"","publisher":{"@id":"https:\/\/industrialphysics.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/industrialphysics.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/industrialphysics.com\/de\/#organization","name":"Industrial Physics","url":"https:\/\/industrialphysics.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","contentUrl":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","width":196,"height":196,"caption":"Industrial Physics"},"image":{"@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/IndustrialPhys","https:\/\/www.linkedin.com\/company\/industrial-physics\/","https:\/\/www.youtube.com\/channel\/UCrx-7K2sYE4ppkqkhAbkO1A"]}]}},"_links":{"self":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/291102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards"}],"about":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/types\/standards"}],"author":[{"embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":3,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/291102\/revisions"}],"predecessor-version":[{"id":496938,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/291102\/revisions\/496938"}],"wp:attachment":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/media?parent=291102"}],"wp:term":[{"taxonomy":"standards_categories","embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards_categories?post=291102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}