{"id":290778,"date":"2025-01-23T06:13:59","date_gmt":"2025-01-23T10:13:59","guid":{"rendered":""},"modified":"2026-10-21T12:03:35","modified_gmt":"2026-10-21T16:03:35","slug":"iso-2811-de","status":"publish","type":"standards","link":"https:\/\/industrialphysics.com\/de\/standards\/iso-2811-de\/","title":{"rendered":"ISO 2811"},"content":{"rendered":"<h2>Einf\u00fchrung in ISO 2811 \u2013 Industrial Physics<\/h2>\n<p><span data-contrast=\"none\">ISO 2811 <\/span><span data-contrast=\"auto\">ist eine internationale <\/span><span data-contrast=\"none\">ISO-Norm<\/span><span data-contrast=\"auto\"> f\u00fcr zuverl\u00e4ssige <\/span><span data-contrast=\"none\">Dichtepr\u00fcfungen<\/span><span data-contrast=\"auto\"> von Farben, Lacken und verwandten Produkten mithilfe eines Metall- oder <\/span><span data-contrast=\"none\">Gay-Lussac-Pyknometers.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"none\">Pyknometer<\/span><span data-contrast=\"auto\"> werden zum Messen und Vergleichen von Dichten \u2013 oder spezifischen Gewichten \u2013 von Fl\u00fcssigkeiten und Feststoffen verwendet. <\/span><span data-contrast=\"none\">Pyknometerflaschen<\/span><span data-contrast=\"auto\">  werden typischerweise aus Glas gefertigt und verf\u00fcgen \u00fcber einen geschliffenen Glasstopfen mit einem Kapillarrohr, durch das Luftblasen entweichen k\u00f6nnen. Sie sind auch aus Metall erh\u00e4ltlich, und Sie k\u00f6nnen beide Typen verwenden, wenn Sie  <\/span><span data-contrast=\"none\">ISO 2811-Pr\u00fcfungen durchf\u00fchren.<\/span><span data-contrast=\"auto\"> <\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Die<\/span><span data-contrast=\"none\"> ISO 2811<\/span><span data-contrast=\"auto\">  Methode ist auf Materialien mit niedriger oder mittlerer Viskosit\u00e4t bei der Pr\u00fcftemperatur beschr\u00e4nkt. Wenn Sie jedoch hochviskose Materialien pr\u00fcfen m\u00fcssen, kann das speziell entwickelte Hubbard-Pyknometer (siehe ISO 3507) verwendet werden.  <\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<h2>Der ISO 2811-Pyknometer-Pr\u00fcfansatz<\/h2>\n<p><span data-contrast=\"auto\">Um einen<\/span><span data-contrast=\"none\"> ISO 2811-Pyknometer-Test <\/span><span data-contrast=\"auto\">durchzuf\u00fchren, m\u00fcssen Sie zun\u00e4chst ein <\/span><span data-contrast=\"none\">Pyknometer<\/span><span data-contrast=\"auto\">  mit einer Probe des zu pr\u00fcfenden Produkts f\u00fcllen. Die Dichte wird aus der Masse des Produkts im  <\/span><span data-contrast=\"none\">Pyknometer<\/span><span data-contrast=\"auto\"> und dem bekannten Volumen des <\/span><span data-contrast=\"none\">Pyknometers<\/span> berechnet.<span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Der Einfluss der Temperatur auf die Dichte ist im Hinblick auf F\u00fcllungseigenschaften \u00e4u\u00dferst bedeutend. Daher ist es f\u00fcr internationale Referenzzwecke unerl\u00e4sslich, eine Pr\u00fcftemperatur zu standardisieren.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<h2>Inhalte der ISO 2811-Pyknometerpr\u00fcfung<\/h2>\n<p><span data-contrast=\"auto\">Die <\/span><span data-contrast=\"none\">ISO 2811<\/span><span data-contrast=\"auto\">-Norm besteht aus den folgenden Teilen: <\/span> <span data-ccp-props=\"{\"> <\/span><\/p>\n<ul>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"2\" data-list-defn-props=\"{\" data-aria-posinset=\"1\" data-aria-level=\"1\"><b><span data-contrast=\"auto\">Teil 1:<\/span><\/b> <span data-contrast=\"none\">Pyknometer-Pr\u00fcf<\/span><span data-contrast=\"auto\">methode<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"2\" data-list-defn-props=\"{\" data-aria-posinset=\"2\" data-aria-level=\"1\"><b><span data-contrast=\"auto\">Teil 2: <\/span><\/b><span data-contrast=\"auto\">Methode mit eingetauchtem K\u00f6rper (Senkgewicht)<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"2\" data-list-defn-props=\"{\" data-aria-posinset=\"3\" data-aria-level=\"1\"><b><span data-contrast=\"auto\">Teil 3: <\/span><\/b><span data-contrast=\"auto\">Oszillationsmethode<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"2\" data-list-defn-props=\"{\" data-aria-posinset=\"4\" data-aria-level=\"1\"><b><span data-contrast=\"auto\">Teil 4:<\/span><\/b><span data-contrast=\"auto\"> Druckbecher-Methode<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<\/ul>\n<h2>Ausr\u00fcstung f\u00fcr Pyknometerpr\u00fcfungen<\/h2>\n<p><b><span data-contrast=\"none\">Metall-Pyknometer  <\/span><\/b><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Wenn Sie sich f\u00fcr ein <\/span><span data-contrast=\"none\">Metall-Pyknometer<\/span><span data-contrast=\"auto\">  entscheiden, sollten Sie mit einem Ger\u00e4t arbeiten, das entweder ein Volumen von 50 cm3 oder 100 cm3 hat, einen kreisf\u00f6rmigen Querschnitt und eine zylindrische Form. Es sollte aus einem glatt bearbeiteten, korrosionsbest\u00e4ndigen Material bestehen und einen dicht schlie\u00dfenden Deckel mit einer \u00d6ffnung in der Mitte haben. Die Innenseite des Deckels selbst sollte konkav ausgef\u00fchrt sein.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><span data-contrast=\"none\">Glas-Pyknometer<\/span><\/b><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Wenn Sie mit einem <\/span><span data-contrast=\"none\">Glas-Pyknometer<\/span><span data-contrast=\"auto\"> arbeiten m\u00f6chten, ben\u00f6tigen Sie einen <\/span><span data-contrast=\"none\">Gay-Lussac<\/span><span data-contrast=\"auto\">  Typ mit einem Volumen im Bereich von 10 cm3 bis 100 cm3. Das  <\/span><span data-contrast=\"none\">Gay-Lussac-Pyknometer<\/span><span data-contrast=\"auto\"> verf\u00fcgt \u00fcber einen Glask\u00f6rper mit einem geschliffenen Kapillarstopfen.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><span data-contrast=\"none\">Analysenwaage<\/span><\/b><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Ihre <\/span><span data-contrast=\"none\">ISO 2811<\/span><span data-contrast=\"auto\">-Analysenwaage sollte bei der Verwendung von<\/span><span data-contrast=\"none\"> Pyknometern <\/span><span data-contrast=\"auto\">unter 50 ml auf 1 mg genau sein oder bei der Verwendung von <\/span><span data-contrast=\"none\">Pyknometern<\/span><span data-contrast=\"auto\"> mit einem Volumen von 50 ml bis 100 ml auf 10 mg genau sein.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><span data-contrast=\"none\">Thermometer<\/span><\/b><br \/>\n<span data-contrast=\"auto\">Das Thermometer, das Sie f\u00fcr <\/span><span data-contrast=\"none\">ISO 2811<\/span><span data-contrast=\"auto\">-Pr\u00fcfungen ben\u00f6tigen, sollte eine Genauigkeit von 0,2\u00b0C haben.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><span data-contrast=\"none\">Temperaturgeregelte Kammer<\/span><\/b><br \/>\n<span data-contrast=\"auto\">Sie ben\u00f6tigen eine Kammer, die Waage, <\/span><span data-contrast=\"none\">Pyknometer<\/span><span data-contrast=\"auto\">  und Pr\u00fcfprobe aufnehmen kann und diese auf der festgelegten oder vereinbarten Temperatur h\u00e4lt. Oder ein Wasserbad, das dieselbe Funktion bietet.  <\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><span data-contrast=\"none\">Zus\u00e4tzliche ISO 2811-Ausr\u00fcstung  <\/span><\/b><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Zus\u00e4tzlich zum richtigen <\/span><span data-contrast=\"none\">Pyknometer<\/span><span data-contrast=\"auto\"> ben\u00f6tigen Sie zur Durchf\u00fchrung eines <\/span><span data-contrast=\"none\">ISO 2811<\/span><span data-contrast=\"auto\">-Tests eine Auswahl typischer Laborger\u00e4te und Glaswaren. <\/span> <span data-ccp-props=\"{\"> <\/span><\/p>\n<h2>Die ISO 2811-Normdokumente<\/h2>\n<p><span data-contrast=\"auto\">In den<\/span><span data-contrast=\"none\"> ISO 2811<\/span><span data-contrast=\"auto\">-Dokumenten sind folgende Inhalte enthalten:<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<ul>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">ISO 2811<\/span><span data-contrast=\"auto\">-Geltungsbereichsbeschreibung<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"auto\">Informationen zur<\/span><span data-contrast=\"none\"> ISO 2811-Pr\u00fcf<\/span><span data-contrast=\"auto\">methodik<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"auto\">Informationen zu den zu verwendenden Ger\u00e4ten  <\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span data-contrast=\"auto\">So bereiten Sie Ihre Proben f\u00fcr die Pr\u00fcfung vor  <\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"5\" data-aria-level=\"1\"><span data-contrast=\"auto\">So berechnen Sie Ihre Ergebnisse  <\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<li data-leveltext=\"\u25cf\" data-font=\"\" data-listid=\"1\" data-list-defn-props=\"{\" data-aria-posinset=\"6\" data-aria-level=\"1\"><span data-contrast=\"auto\">Standardformat f\u00fcr den Pr\u00fcfbericht<\/span><span data-ccp-props=\"{\"> <\/span><\/li>\n<\/ul>\n<h2>ISO 2811-Pr\u00fcfger\u00e4te<\/h2>\n<p><span data-contrast=\"none\">Wie kann Industrial Physics Ihre <\/span><span data-contrast=\"none\">ISO 2811-Pr\u00fcfungen verbessern?<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/product\/specific-gravity-cups-pycnometers\/\"><b><span data-contrast=\"none\">TQC Sheen Pyknometer (Spezifisches-Gewicht-Becher)<\/span><\/b><\/a><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Unser Sortiment an <\/span><span data-contrast=\"none\">Pyknometern<\/span><span data-contrast=\"auto\">  unserer Farblabor-Spezialistenmarke TQC Sheen ist genau das Richtige, um das spezifische Gewicht oder die Dichte von beschichtungen, Pasten oder \u00e4hnlichen Fl\u00fcssigkeiten zu bestimmen. Sie sind in eloxiertem Aluminium und Edelstahl in den Ausf\u00fchrungen 100 ml und 50 ml erh\u00e4ltlich, und alle Modelle werden mit einem Kalibrierzertifikat geliefert.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/de\/produkt\/druck-dichte-becher\/\"><b><span data-contrast=\"none\">TQC Sheen Druck-Dichtebecher<\/span><\/b><\/a><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><span data-contrast=\"auto\">Der TQC Sheen Druck-Dichtebecher wurde entwickelt, um hochpr\u00e4zise Messungen des spezifischen Gewichts der Dichte einer Fl\u00fcssigkeit mit hoher Wiederholbarkeit zu erm\u00f6glichen.<\/span><span data-ccp-props=\"{\"> <\/span><\/p>\n<p><b><i><span data-contrast=\"none\">Ihr globaler Partner f\u00fcr Pr\u00fcf- und Messtechnik f\u00fcr ISO 2811<\/span><\/i><\/b><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Einf\u00fchrung in ISO 2811 \u2013 Industrial Physics ISO 2811 ist eine internationale ISO-Norm f\u00fcr zuverl\u00e4ssige Dichtepr\u00fcfungen von Farben, Lacken und verwandten Produkten mithilfe eines Metall- oder &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/industrialphysics.com\/de\/standards\/iso-2811-de\/\" class=\"more-link\"><span class=\"screen-reader-text\">\u201eISO 2811\u201c <\/span>weiterlesen<\/a><\/p>\n","protected":false},"author":148,"featured_media":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"standards_categories":[11813,11817],"class_list":["post-290778","standards","type-standards","status-publish","hentry","standards_categories-industry-standards-de","standards_categories-international-standards-de","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Physics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Physics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@IndustrialPhys\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\n\t    \"@context\": \"https:\\\/\\\/schema.org\",\n\t    \"@graph\": [\n\t        {\n\t            \"@type\": \"CollectionPage\",\n\t            \"@id\": null,\n\t            \"url\": \"\",\n\t            \"name\": \"\",\n\t            \"isPartOf\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\"\n\t            },\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"WebSite\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"description\": \"\",\n\t            \"publisher\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\"\n\t            },\n\t            \"potentialAction\": [\n\t                {\n\t                    \"@type\": \"SearchAction\",\n\t                    \"target\": {\n\t                        \"@type\": \"EntryPoint\",\n\t                        \"urlTemplate\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/?s={search_term_string}\"\n\t                    },\n\t                    \"query-input\": {\n\t                        \"@type\": \"PropertyValueSpecification\",\n\t                        \"valueRequired\": true,\n\t                        \"valueName\": \"search_term_string\"\n\t                    }\n\t                }\n\t            ],\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"Organization\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"logo\": {\n\t                \"@type\": \"ImageObject\",\n\t                \"inLanguage\": \"de\",\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\n\t                \"url\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"contentUrl\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"width\": 196,\n\t                \"height\": 196,\n\t                \"caption\": \"Industrial Physics\"\n\t            },\n\t            \"image\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"\n\t            },\n\t            \"sameAs\": [\n\t                \"https:\\\/\\\/x.com\\\/IndustrialPhys\",\n\t                \"https:\\\/\\\/www.linkedin.com\\\/company\\\/industrial-physics\\\/\",\n\t                \"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCrx-7K2sYE4ppkqkhAbkO1A\"\n\t            ]\n\t        }\n\t    ]\n\t}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Physics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"de_DE","og_type":"article","og_site_name":"Industrial Physics","twitter_card":"summary_large_image","twitter_site":"@IndustrialPhys","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":null,"url":"","name":"","isPartOf":{"@id":"https:\/\/industrialphysics.com\/de\/#website"},"inLanguage":"de"},{"@type":"WebSite","@id":"https:\/\/industrialphysics.com\/de\/#website","url":"https:\/\/industrialphysics.com\/de\/","name":"Industrial Physics","description":"","publisher":{"@id":"https:\/\/industrialphysics.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/industrialphysics.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/industrialphysics.com\/de\/#organization","name":"Industrial Physics","url":"https:\/\/industrialphysics.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","contentUrl":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","width":196,"height":196,"caption":"Industrial Physics"},"image":{"@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/IndustrialPhys","https:\/\/www.linkedin.com\/company\/industrial-physics\/","https:\/\/www.youtube.com\/channel\/UCrx-7K2sYE4ppkqkhAbkO1A"]}]}},"_links":{"self":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/290778","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards"}],"about":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/types\/standards"}],"author":[{"embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":3,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/290778\/revisions"}],"predecessor-version":[{"id":497430,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/290778\/revisions\/497430"}],"wp:attachment":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/media?parent=290778"}],"wp:term":[{"taxonomy":"standards_categories","embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards_categories?post=290778"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}