{"id":289864,"date":"2025-01-23T06:13:59","date_gmt":"2025-01-23T10:13:59","guid":{"rendered":""},"modified":"2026-07-28T04:03:00","modified_gmt":"2026-07-28T08:03:00","slug":"f2622-0-de","status":"publish","type":"standards","link":"https:\/\/industrialphysics.com\/de\/standards\/f2622-0-de\/","title":{"rendered":"ASTM F2622"},"content":{"rendered":"<h2>Einf\u00fchrung in die ASTM F2622 &#8211; Industrial Physics<\/h2>\n<p>ASTM F2622 ist die Standardtestmethode zur Bestimmung der <strong>Sauerstoffdurchl\u00e4ssigkeit (OTR)<\/strong> von flexiblen Barrierematerialien unter Verwendung eines <strong>coulometrischen Sensors<\/strong>. Diese Methode bietet eine pr\u00e4zise, wiederholbare M\u00f6glichkeit zu messen, wie viel Sauerstoff durch Folien, Laminate und Verpackungsstrukturen dringt &#8211; wichtige Daten f\u00fcr die Vorhersage der Haltbarkeit, die Validierung der Performanz und die Gew\u00e4hrleistung der Produktstabilit\u00e4t.<\/p>\n<p>Ganz gleich, ob Sie Lebensmittel, Pharmazeutika, medizinische Ger\u00e4te oder empfindliche Industrieprodukte verpacken, die ASTM F2622 bietet Ihnen einen zuverl\u00e4ssigen Rahmen f\u00fcr die Bewertung der Integrit\u00e4t von Sauerstoffbarrieren.<\/p>\n<h3>Was deckt ASTM F2622 ab?<\/h3>\n<p>ASTM F2622 beschreibt Verfahren zur Messung der Sauerstoffdurchl\u00e4ssigkeit unter Verwendung eines <strong>coulometrischen Detektors<\/strong> bei kontrollierter Temperatur und Feuchtigkeit. Die wichtigsten Elemente sind:<\/p>\n<ul>\n<li>Konditionierung und Montage von Barriereproben<\/li>\n<li>Kontrolle der Testtemperatur und der relativen Luftfeuchtigkeit<\/li>\n<li>Messung der Sauerstoffpermeation mit einem coulometrischen Sensor<\/li>\n<li>Berechnung von OTR-Werten f\u00fcr die Qualit\u00e4tskontrolle und den Materialvergleich<\/li>\n<li>Sicherstellung konsistenter Testbedingungen und Wiederholbarkeit<\/li>\n<\/ul>\n<p>Die Methode gilt f\u00fcr:<\/p>\n<ul>\n<li>Flexible Folien und Laminate<\/li>\n<li>Beschichtetes und unbeschichtetes Verpackungsmaterial<\/li>\n<li>Strukturen mit hoher Barriere und niedriger Barriere<\/li>\n<li>F&amp;E-, QC- und Verpackungsvalidierungsumgebungen<\/li>\n<\/ul>\n<p>ASTM F2622 wird in vielen Industriezweigen verwendet, in denen die Sauerstoffeinwirkung die Produktqualit\u00e4t, Sicherheit oder Haltbarkeit beeintr\u00e4chtigt.<\/p>\n<h3>Wo ASTM F2622 verwendet wird<\/h3>\n<p>Dieser Standard wird h\u00e4ufig verwendet in:<\/p>\n<ul>\n<li>Verpackungen f\u00fcr Lebensmittel und Getr\u00e4nke<\/li>\n<li>Pharmazeutische und medizintechnische Verpackungen<\/li>\n<li>Industrielle und spezielle Barrierematerialien<\/li>\n<li>F&amp;E-Labors f\u00fcr Verpackungen<\/li>\n<li>Programme zur Materialqualifizierung und Lieferanten\u00fcberpr\u00fcfung<\/li>\n<\/ul>\n<p>Es unterst\u00fctzt sowohl routinem\u00e4\u00dfige QC-Tests als auch fortgeschrittene Studien zur Performance der Barriere.<\/p>\n<h3>Warum Sauerstoff\u00fcbertragungstests wichtig sind<\/h3>\n<p>Das Verst\u00e4ndnis der Sauerstoffdurchl\u00e4ssigkeit ist wichtig f\u00fcr:<\/p>\n<ul>\n<li>Vorhersage von <strong>Haltbarkeit und Produktstabilit\u00e4t<\/strong><\/li>\n<li>Validierung der <strong>Performanz<\/strong> von Folien und Laminaten<\/li>\n<li>Vergleich von <strong>Materialstrukturen und Beschichtungen<\/strong><\/li>\n<li>Sicherstellung der <strong>Einhaltung von Vorschriften und Kunden<\/strong><\/li>\n<li>Reduzierung von <strong>Verderb, Oxidation und Produktausf\u00e4llen<\/strong><\/li>\n<\/ul>\n<p>OTR-Tests helfen Herstellern, die richtigen Materialien auszuw\u00e4hlen und eine gleichbleibende Performanz der Verpackung zu gew\u00e4hrleisten.<\/p>\n<h3>Testl\u00f6sungen f\u00fcr ASTM F2622<\/h3>\n<p>Industrial Physics&#8217; bietet mehrere OTR-Analysatoren an, die direkt mit den Anforderungen der ASTM F2622 f\u00fcr coulometrische Sensoren \u00fcbereinstimmen:<\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/de\/produkt\/oxysense-8102-sauerstoff-transmission-rate-analyzer\/\"><strong>OxySense 8102e Sauerstofftransmissionsraten-Analysator<\/strong><\/a><\/p>\n<p>Ein hochleistungsf\u00e4higes OTR-Analyseger\u00e4t f\u00fcr pr\u00e4zise, wiederholbare Messungen unter Verwendung einer <strong>nicht verbrauchbaren optischen Sauerstoffsensortechnologie<\/strong>. Ideal f\u00fcr flexible Folien, beschichtete Materialien und Hochbarrierestrukturen. Der 8102E unterst\u00fctzt kontrollierte Temperatur- und Feuchtigkeitstests gem\u00e4\u00df ASTM F2622.<\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/de\/produkt\/8101e-oxysense-sauerstoff-transmissionsraten-analysator\/\"><strong>OxySense 8101e Sauerstofftransmissionsraten-Analysator<\/strong><\/a><\/p>\n<p>Eine kompakte, kosteng\u00fcnstige OTR-L\u00f6sung f\u00fcr die routinem\u00e4\u00dfige Qualit\u00e4tskontrolle und den Materialvergleich. Der 8101E verwendet die gleiche optische Sensortechnologie wie der 8102E und liefert genaue Daten zur Sauerstoffpermeation ohne Kalibriergase oder Verbrauchsmaterialien.<\/p>\n<p><a href=\"https:\/\/industrialphysics.com\/de\/produkt\/8700-8701-oxysense-sauerstoff-permeabilitaets-analysator\/\"><strong>OxySense 8700\/8701 Sauerstoffdurchl\u00e4ssigkeits-Analysator<\/strong><\/a><\/p>\n<p>Ein vielseitiges System zur Messung der Sauerstoffdurchl\u00e4ssigkeit sowohl von <strong>Folien als auch von fertigen Verpackungen<\/strong>. Die 8700\/8701 Plattform unterst\u00fctzt ASTM F2622-Tests und erm\u00f6glicht gleichzeitig die Analyse ganzer Verpackungen &#8211; ideal f\u00fcr Teams, die komplette Verpackungssysteme und nicht nur Materialien validieren.<\/p>\n<p>Zusammen geben Ihnen diese OxySense-Instrumente ein komplettes Instrumentarium zur Bewertung der Performanz von Sauerstoffbarrieren bei Materialien, Strukturen und fertigen Verpackungen.<\/p>\n<h3>Ihr globaler Partner f\u00fcr Tests und Messungen nach ASTM F2622<\/h3>\n<p>Industrial Physics unterst\u00fctzt Verpackungshersteller, Verarbeiter und Markeninhaber mit den Werkzeugen und dem Fachwissen, die zur Bewertung der Sauerstoffdurchl\u00e4ssigkeit gem\u00e4\u00df ASTM F2622 erforderlich sind. Von hochpr\u00e4zisen OTR-Analysatoren bis hin zu Systemen f\u00fcr die Durchl\u00e4ssigkeit ganzer Verpackungen helfen wir Ihnen, sicherzustellen, dass Ihre Materialien die Performanz liefern, auf die Ihre Produkte angewiesen sind.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Einf\u00fchrung in die ASTM F2622 &#8211; Industrial Physics ASTM F2622 ist die Standardtestmethode zur Bestimmung der Sauerstoffdurchl\u00e4ssigkeit (OTR) von flexiblen Barrierematerialien unter Verwendung eines coulometrischen Sensors. &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/industrialphysics.com\/de\/standards\/f2622-0-de\/\" class=\"more-link\"><span class=\"screen-reader-text\">\u201eASTM F2622\u201c <\/span>weiterlesen<\/a><\/p>\n","protected":false},"author":148,"featured_media":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"standards_categories":[11813,11817],"class_list":["post-289864","standards","type-standards","status-publish","hentry","standards_categories-industry-standards-de","standards_categories-international-standards-de","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Physics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:site_name\" content=\"Industrial Physics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@IndustrialPhys\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\n\t    \"@context\": \"https:\\\/\\\/schema.org\",\n\t    \"@graph\": [\n\t        {\n\t            \"@type\": \"CollectionPage\",\n\t            \"@id\": null,\n\t            \"url\": \"\",\n\t            \"name\": \"\",\n\t            \"isPartOf\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\"\n\t            },\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"WebSite\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#website\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"description\": \"\",\n\t            \"publisher\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\"\n\t            },\n\t            \"potentialAction\": [\n\t                {\n\t                    \"@type\": \"SearchAction\",\n\t                    \"target\": {\n\t                        \"@type\": \"EntryPoint\",\n\t                        \"urlTemplate\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/?s={search_term_string}\"\n\t                    },\n\t                    \"query-input\": {\n\t                        \"@type\": \"PropertyValueSpecification\",\n\t                        \"valueRequired\": true,\n\t                        \"valueName\": \"search_term_string\"\n\t                    }\n\t                }\n\t            ],\n\t            \"inLanguage\": \"de\"\n\t        },\n\t        {\n\t            \"@type\": \"Organization\",\n\t            \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#organization\",\n\t            \"name\": \"Industrial Physics\",\n\t            \"url\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/\",\n\t            \"logo\": {\n\t                \"@type\": \"ImageObject\",\n\t                \"inLanguage\": \"de\",\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\n\t                \"url\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"contentUrl\": \"https:\\\/\\\/industrialphysics.com\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/favicon-196-1.png\",\n\t                \"width\": 196,\n\t                \"height\": 196,\n\t                \"caption\": \"Industrial Physics\"\n\t            },\n\t            \"image\": {\n\t                \"@id\": \"https:\\\/\\\/industrialphysics.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"\n\t            },\n\t            \"sameAs\": [\n\t                \"https:\\\/\\\/x.com\\\/IndustrialPhys\",\n\t                \"https:\\\/\\\/www.linkedin.com\\\/company\\\/industrial-physics\\\/\",\n\t                \"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCrx-7K2sYE4ppkqkhAbkO1A\"\n\t            ]\n\t        }\n\t    ]\n\t}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Physics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"\/","og_locale":"de_DE","og_type":"article","og_site_name":"Industrial Physics","twitter_card":"summary_large_image","twitter_site":"@IndustrialPhys","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":null,"url":"","name":"","isPartOf":{"@id":"https:\/\/industrialphysics.com\/de\/#website"},"inLanguage":"de"},{"@type":"WebSite","@id":"https:\/\/industrialphysics.com\/de\/#website","url":"https:\/\/industrialphysics.com\/de\/","name":"Industrial Physics","description":"","publisher":{"@id":"https:\/\/industrialphysics.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/industrialphysics.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/industrialphysics.com\/de\/#organization","name":"Industrial Physics","url":"https:\/\/industrialphysics.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","contentUrl":"https:\/\/industrialphysics.com\/wp-content\/uploads\/2021\/08\/favicon-196-1.png","width":196,"height":196,"caption":"Industrial Physics"},"image":{"@id":"https:\/\/industrialphysics.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/IndustrialPhys","https:\/\/www.linkedin.com\/company\/industrial-physics\/","https:\/\/www.youtube.com\/channel\/UCrx-7K2sYE4ppkqkhAbkO1A"]}]}},"_links":{"self":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/289864","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards"}],"about":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/types\/standards"}],"author":[{"embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":4,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/289864\/revisions"}],"predecessor-version":[{"id":488843,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards\/289864\/revisions\/488843"}],"wp:attachment":[{"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/media?parent=289864"}],"wp:term":[{"taxonomy":"standards_categories","embeddable":true,"href":"https:\/\/industrialphysics.com\/de\/wp-json\/wp\/v2\/standards_categories?post=289864"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}